ATTENTION!!! In order for your Steam Generator to be commissioned, the installation and connection
procedures required on-site must be carried out completely. The pictures of your gas opening certificate and
the installations and connections you have made (steam installation, condensate installation, water
installation, electrical installation, blowdown installation and smokestack connection) should be sent to our
company.
c – Warranty and Service
✓In order for the warranty to be valid, the 'Warranty Certificate' must be approved by the manufacturer from
which you purchased the device. Improper installation, maintenance or usage is not covered by the warranty. The
failures caused by the coating of the heat transfer parts of the steam generator with lime and / or similar
substances or caused by corrosion and all other water-related failures are not covered by the warranty.
d – General Characteristics
✓It is a slant type device with water pipes. Generates steam in a very short time. It has a high efficiency, a long life and it
is fully automatic. It consists of a spiral curved, intertwined double-row coil (serpentine). The water volume is extremely
small. According to TS 2736, Annex 2. Article 2.11, there is no harm in placing it in the building without a separate boiler
room. It has a highly advanced security equipment. The body of the steam generator is insulated by covering the static
powder coated hair on rock wool.
✓With JENESIS Steam Generators, high efficiency monoblock burners with widespread service networks which have CE
and TSE are preferred. SPECK triplex piston pumps are used as feed water pumps.
✓Safety valve ensures safe operation of the system by releasing steam at possible pressure increases.
✓Safety switch allows the system (burner and pump) to stop when the set pressure is reached in case of failure of the
operating switch.
✓In addition to displaying the steam temperature from the digital display during operation, the steam thermostat stops
the system if the generator exceeds the maximum steam temperature set in case of possible dehydration.
✓Fe - Const temperature sensing element is used to measure the steam temperature accurately.
✓The smokestack gas thermostat will display the flue gas temperature from the digital display during operation, and the
system will stop and operate if the value exceeds the maximum smokestack gas temperature allowed by the municipality
and other public institutions.
✓Fe - Const elements and special cable are used to measure the smokestack gas temperature as well as the steam
temperature.