7.3. Command

7.3.1 Power Control Command and Data
FUNCTION
MCMD
SCMD
POWER ON/OFF
0x0100
AUTO POWER ON ON/OFF
0x0110
DIALOG BOX OPEN
0x01F0
(AUTO POWER)
DIALOG BOX OPEN
0x01F0
(AUTO POWER)
7.3.2 Display Control Command and Data
FUNCTION
MCMD
SCMD
INPUT SOURCE
0x0210
DIALOG BOX OPEN
0x02F0
DIALOG BOX OPEN
0x02F0
(MONITOR DATA)
RESET
0x02FE
(W/ DEFAULT DATA)
7.3.3 Picture Control Command and Data
FUNCTION
MCMD
SCMD
BRIGHTNESS
0x0300
CONTRAST
0x0301
SHARPNESS
0x0302
BACKLIGHT
0x0310
GAMMA
0x0320
COLOR TEMPERATURE
0x0321
USER RED/GREEN/BLUE
0x0322
HUE
0x0323
SATURATION
0x0324
COLOR RANGE
0x0334
- 70 -
DATA
REMARK
D1 : 0x01-ON, 0x00-OFF
D1 : 0x01-ON, 0x00-OFF
-
READ ONLY
D1 : 0x01-ON, 0x00-OFF
RECEIVE ONLY
DATA
REMARK
D1 : 0x30-DP, 0x20-HDMI, 0x10-DVI
-
READ ONLY
RECEIVE ONLY
D1 : 0x00 (FIXED, NOT USED)
D2 : POWER ON INPUT
WRITE ONLY
D3 : ROTATE
DATA
REMARK
D1 : 0 ~ 100 (DEFAULT 50)
D1 : 0 ~ 100 (DEFAULT 50)
D1 : 0 ~ 4 (DEFAULT 2)
D1 : 0 ~ 100 (DEFAULT 90)
D1 : 0x00-OFF, 0x01-1.8, 0x02-2.0
0x03-2.2, 0x04-2.4
D1 : 0x00-USER, 0x03-STUDIO, 0x41-6500,
0x5D-9300, 0x64-10000
D1 : 0x00-RED, 0x02-GREEN, 0x03-BLUE
D2 : 0 ~ 255 (DEFAULT 127)
D1 : 0 ~ 100 (DEFAULT 50)
D1 : 0 ~ 100 (DEFAULT 50)
D1: 0x00(Full), 0x01(LIMIT)
FUNCTION
MCMD
SCMD
DIALOG BOX OPEN
0x03F0
-
DIALOG BOX OPEN
D1 : BRIGHTNESS
0x03F0
(W/ MONITOR DATA)
D2 : CONTRAST
RESET
D3 : SHARPNESS
(W/ DEFAULT DATA)
D4 : BACKLIGHT
D5 : GAMMA
D6 : COLOR TEMPERATURE
0x03FE
D7 : USER COLOR TEMPERATURE RED
D8 : USER COLOR TEMPERATURE GREEN
D9 : USER COLOR TEMPERATURE BLUE
D10 : HUE
D11 : SATURATION
7.3.4 Multi Display Control Command and Data
FUNCTION
MCMD
SCMD
NEW ID SET
D1 : NEW GROUP ID NO.
0x0600
D2 : NEW MONITOR ID NO. (MID1)
D3 : NEW MONITOR ID NO. (MID2)
AUTO ID
0x0601
-
MULTI SCALE
D1 : TOTAL COLUMN NO.
D2 : TOTAL ROW NO.
0x0610
D3 : GROUP ID NO.
D4 : MONITOR ID NO. (MSB)
D5 : MONITOR ID NO. (LSB)
BEZEL COMP. ON/OFF
0x0620
D1 : 0x01-ON, 0x00-OFF
BEZEL COMP. VALUE
0x0621
D1 : 0 ~ 10 (DEFAULT 0)
DIALOG BOX OPEN
0x06F0
-
DIALOG BOX OPEN
D1 : BEZEL COMP. ON/OFF
0x06F0
(W/ MONITOR DATA)
D2 : BEZEL COMP. VALUE
RESET
D3 : POWER ON DELAY
0x06FE
(W/ DEFAULT DATA)
DATA
REMARK
READ ONLY
RECEIVE ONLY
WRITE ONLY
DATA
REMARK
WRITE ONLY
WRITE ONLY
READ ONLY
RECEIVE ONLY
WRITE ONLY
- 71 -