Orion OLMU-K4650 User Manual

Orion OLMU-K4650 User Manual

Infinitely expandable mlcd

Advertisement

A revolutionary MLCD
MLCD
A revolutionary MLCD
Infinitely Expandable
Infinitely Expandable MLCD
.
ORION CO.,LTD
www.oriondisplay.net
Address: 217, 1gongdan-ro, Gumi-si, Gyeongsangbuk-do, Korea
Tel : +82-2-6678-8533, Fax: +82-2-6678-8599
OLMU-K4650|OLMU-K4670|OLMU-K5550|OLMU-K5570
User's Manual
please read through this user's manual for safety before installing this product

Advertisement

Table of Contents
loading

Summary of Contents for Orion OLMU-K4650

  • Page 1 A revolutionary MLCD MLCD A revolutionary MLCD Infinitely Expandable Infinitely Expandable MLCD ORION CO.,LTD www.oriondisplay.net Address: 217, 1gongdan-ro, Gumi-si, Gyeongsangbuk-do, Korea Tel : +82-2-6678-8533, Fax: +82-2-6678-8599 OLMU-K4650|OLMU-K4670|OLMU-K5550|OLMU-K5570 User's Manual please read through this user's manual for safety before installing this product...
  • Page 2 MLCD Infinitely Expandable Features ▶ Enjoy a wide flat screen with high brightness and high quality. Notice to users ▶ Easy to install and move due to its thin design Class A digital device ▶ Enjoy your favorite programs with various split-screen features simultaneously presenting It is a device designed for business purpose with a safety certificate for electromagnetic interfere several programs.
  • Page 3: Table Of Contents

    To reduce the risk of electric shock, do not perform any servicing other than that contained in the 10. Specification…....................... operating instructions unless you are qualified to do so. 11. Regulatory Information....................12. Dimension........................76 12.1. OLMU-K4650/OLMU-K4670.....................76 12.2. OLMU-K5550/OLMU-K5570.....................77 - 2 - - 3 -...
  • Page 4: European Union Disposal Information

    återvinns på ett riktigt sätt hjälper du till med att förhindra mö mpäristölle ja ihmisille koituvia negatiivisia seuraamuksia, joita sen vääränlain - The sliding Universal Unit of ORION is recommended for easier service. jliga negative konsekvenser för miljön och mänsklig hälsa. Det kan annars orsak en hävittäminen voi aiheuttaa.
  • Page 5: Cleaning And Maintenance

    MLCD Infinitely Expandable www.oriondisplay.net Clearance for Ventilation Cleaning and Maintenance ※ ※ - Regularly clean off the vent holes in the back of monitor sets. - When you install monitor make sure there is at least 20cm clearance for effective If the vent holes and the fan air holes are clogged with dust, it prevents the air ventilation and do not seal off monitor sets.
  • Page 6: Handle With Caution

    MLCD Infinitely Expandable www.oriondisplay.net ※ Please keep following instructi ※ Handle with Caution. on for panel protection without -Shock/Impact on the set's sides will result in internal Warning Warning exception. circuit damages. -The edge/bottom of the panel are fragile. - This product can be damaged even with minor impact Use shock-absorbing pads or rugs for laying down the for its nature.
  • Page 7: How To Carry

    MLCD Infinitely Expandable www.oriondisplay.net ※ How to carry ※ Application information If static images are displayed on the screen for a long time, it causes burn-in image. It always needs two persons to carry or install Please keep the following instruction to optimize the lifetime and functions of the monitor .
  • Page 8: Attention For Installing

    MLCD Infinitely Expandable www.oriondisplay.net ※ Attention for Installing Warning Fixed • Avoid giving a shock or damage at LCD • Keep all LCDs balanced in vertical or • Avoid that LCD is twisted. • Avoid that LCD outside is shocked or corner or other parts during setting horizontal force after setting damaged by sharp thing.
  • Page 9: Safety Precautions

    MLCD Infinitely Expandable www.oriondisplay.net Safety Precautions • If it operates abnormally, stop using it • Do not place any liquid-containing • Do not pull out or hang down the • Do not lean against the product or keep • Do not put any foreign material into •...
  • Page 10: Names

    MLCD Infinitely Expandable www.oriondisplay.net Names ▶ ▶ Front Input Ports ❿ ❾ 1. AC IN 6. RS232C OUT ▶ Rear AC 100V ~ 240V, 50/60Hz Display control via COM port ❽ 2. A/S (D-Sub 9pin, MALE) Only for Firmware upgrade. 7.
  • Page 11: How To Connect Cables

    MLCD Infinitely Expandable www.oriondisplay.net How to Connect Cables • Do not connect/disconnect cables while monitor or other external equipments are turned on. • First turn off the power all the attached equipment and make connections. • Make sure the power cord is inserted properly into the power inlet to prevent unexpected pullout of the cord.
  • Page 12: Connection Of Multiple (For Dp In)

    MLCD Infinitely Expandable www.oriondisplay.net 3.3. Connection of Multiple (for HDMI in) 3.2. Connection of Multiple (for DP in) • It is recommended you purchase an HDMI-certified cable. Otherwise, the screen may • Image quality can be affected by cable or signal quality. appear blank or a connection error may occur.
  • Page 13: Connection Of Multiple (For Dvi In)

    MLCD Infinitely Expandable www.oriondisplay.net 3.4. Connection of Multiple (for DVI in) 3.5. Connection of Control Cable • Image quality can be affected by cable or signal quality. • Control signal transmission can be connected by 3 different methods. (RS-232C or Ethernet or IR) •...
  • Page 14: Id Setting

    MLCD Infinitely Expandable www.oriondisplay.net ID Setting 3.5.2. Connection of Ethernet Cable • Refer to the next chapter for OSW use. • In case of Ethernet connection, the control PC should be connected to one of monitor sets with Ethernet cable.For the connection between the monitor sets, they should be •...
  • Page 15: Random Connection

    MLCD Infinitely Expandable www.oriondisplay.net Click “MULTI → ID” 4.2. Random Connection 2. Click "AUTO ID SET" button in "ID" tab to complete ID setting. ㆍIt is the random RS-232C cable connection regardless of the order of ID numbers. RS232C IN RS232C RS232C RS232C OUT...
  • Page 16 MLCD Infinitely Expandable www.oriondisplay.net Click “MULTI → ID”. 4. Identify the IDs of all connected MLCD sets by clicking "INFO" button in Broadcast. 2. Select another number, which is not in use, for “AUTO GROUP ID" and click "AUTO ID SET" in 5.
  • Page 17 MLCD Infinitely Expandable www.oriondisplay.net 7. Identify the IDs on the right MLCD set of upper left corner MLCD set in the same way as the 9. Repeat the above 7) and 8) procedures for the rest of displays in the same order as the above 4) procedure.
  • Page 18: Osd Menu

    MLCD Infinitely Expandable www.oriondisplay.net OSD Menu 5.1. Picture Menu 5.2. Input Menu • Use the Input Source menu to select between different video inputs that are be connected to • Use this menu to activate Brightness/Contrast/sharpness and the luminance of the the monitor.
  • Page 19: Schedule Menu

    MLCD Infinitely Expandable www.oriondisplay.net 5.4. Multi-Display Menu 5.3. Schedule Menu • Control multi-scaling functions in this menu. • Use this function to reserve the time when the monitor turned On or Off. Picture Input Schedule Multi-Display Multi-Display Picture Input Schedule 23:04 ON/OFF Schedule On/Off...
  • Page 20: Other Menu

    MLCD Infinitely Expandable www.oriondisplay.net 5.5. Other Menu 5.6. Information Menu • Reset of the OSD settings, menu time, transparency, position and rotation of the OSD can be • The informaton of input source is shown adjusted in other menu. Other Information Other Information...
  • Page 21: Setting And Operation Of Osw

    (v1.0.6) for your product at the installation screen, it will create a new folder at C:\Program Files \ORION and an icon on your computer screen. • Select proper version for your product and start installation • By double clicking the ORION OSW (v ) icon, the initial screen image of OSW 1.0.6...
  • Page 22 MLCD Infinitely Expandable www.oriondisplay.net 6.2.1 Main Menu 6.2.2 Multi Panel • This is a panel for selecting monitor. • It can help for controlling ① POWER ① Power On/Off. ② INPUT SOURCE ② Input Source.(DP , HDMI, DVI, AUTO) ③ MONITOR CONFIGURATION ③...
  • Page 23: Communication Configuration

    MLCD Infinitely Expandable www.oriondisplay.net 6.3. Communication Configuration 6.3.3. Socket Setup 6.3.1. COM Port For OSW • Com Port connects or disconnects the communication between PC and MLCD. 1. Execute the OSW. • Connect MLCD to PC Com Port via RS-232C cable. 2.
  • Page 24 MLCD Infinitely Expandable www.oriondisplay.net 6.3.4. LAN Port For MLCD 4. Click “ OTHER → LAN “ 6.3.4.1 In case of connection to a LAN Hub • This function is used to control the MLCD via LAN PORT. • During the setting process, MLCD and control PC should be connected via RS-232C cable only.
  • Page 25 MLCD Infinitely Expandable www.oriondisplay.net 6. Save the IP address by clicking “SET TCP/IP” after type-in. 6.3.4.2. In case of connection to user's computer ■ Check the network informations 1. Execute the OSW. 2. After Serial Connection, Turn on the MLCD. 3.
  • Page 26: Screen Configuration

    MLCD Infinitely Expandable www.oriondisplay.net 6.4. Screen Configuration ■ Input column/row number of the MLCD Matrix. 6. Input the network information of the user’s PC to be identical with MLCD set. • However, the final digit of the IP address must be different. Column/row can be selected within the range from 1 to 16.
  • Page 27: Explanation Of The Command Transmission Method

    MLCD Infinitely Expandable www.oriondisplay.net • 6.5. Explanation of the command transmission method. POWER : “ POWER ON/OFF " button is to control power of selected MLCD Sets. ■ Normal Transmission Method. You select MLCD sets in "Screen Configuration Window" clicking the left button of the mouse. Maybe you want to select more than one MLCD set, drag the mouse.
  • Page 28 MLCD Infinitely Expandable www.oriondisplay.net • INPUT SOURCE : To select one of input sources from DP, HDMI, DVI, AUTO Port. • POSITION : To change monitor position.(only one monitor) 1. Select → Screen configuration window 2. Click the “Change” button after change the position number •...
  • Page 29: Control

    MLCD Infinitely Expandable www.oriondisplay.net 6.7. Control 3. Select → Screen configuration window 6.7.1. Power ON Control • Go to “OTHER → POWER" to control power related operation. 4. Click the “Change” button after change the position number ID 1 ID 2 ID 1 ID 2 ID 3...
  • Page 30 MLCD Infinitely Expandable www.oriondisplay.net 6.7.2. Display Control 6.7.3. Picture Control • • To use Picture Control, go to “ APPLICATION → PICTURE ". Go to “OTHER → DISPLAY" to control display related operation. • DISPLAY RESET : Reset of setting value to default. - 56 - - 57 -...
  • Page 31 MLCD Infinitely Expandable www.oriondisplay.net • 6.7.4. FAN Control BRIGHTNESS : Brightness adjusts the brightness of the monitor . (0~100) • • Go to “ OTHER → FAN " to control fan related operation. CONTRAST : Contrast adjusts the difference between darkness and lightness on the monitor. (0~100) •...
  • Page 32 MLCD Infinitely Expandable www.oriondisplay.net 6.7.5. LOCK Control 6.7.6 Help • Go to “ OTHER → LOCK " to control lock operation. • Go to “ APPLICATION → HELP “ to check model information • IR Lock : IR (Remote Controller) Lock On or Off - 60 - - 61 -...
  • Page 33 MLCD Infinitely Expandable www.oriondisplay.net • • Model Info : Click → “ GET ” button to check model information About OSW : Click → “ About OSW ” tab to check osw information • TAG NAME SET 1. Select the panel 2.
  • Page 34 MLCD Infinitely Expandable www.oriondisplay.net 6.7.7. Bezel Control • Bezel Compensation : Bezel Compensation On/Off • Go to “ OTHER → Bezel Comp “ to control Bezel Compensation • Bezel Comp Value : Compensating the frame width.(0~30) - 64 - - 65 -...
  • Page 35: Protocol

    MLCD Infinitely Expandable www.oriondisplay.net PROTOCOL 7.2. Protocol Format 2.1 Send Protocol Format ■ Introduction COMMAND DATA - This document contains the communication PROTOCOL between LCD and its control devices for better use. MCMD SCMD MID1 MID2 … - It focuses on the brief functional explanation and communication protocol without detailed technical matters.
  • Page 36: Command

    MLCD Infinitely Expandable www.oriondisplay.net 7.3. Command 3.1 Power Control Command and Data FUNCTION MCMD SCMD DATA REMARK DIALOG BOX OPEN 0x03F0 READ ONLY POWER ON/OFF 0x0100 D1 : 0x01-ON, 0x00-OFF DIALOG BOX OPEN D1 : BRIGHTNESS RECEIVE ONLY 0x03F0 AUTO POWER ON ON/OFF 0x0110 D1 : 0x01-ON, 0x00-OFF (W/ MONITOR DATA)
  • Page 37 MLCD Infinitely Expandable www.oriondisplay.net 3.5 OSD Control Command and Data 3.8 Model Information Command and Data FUNCTION MCMD SCMD DATA REMARK FUNCTION MCMD SCMD DATA REMARK INFORMATION OSD ON 0x0710 WRITE ONLY SET TAG NAME 0x0031 D1~D16 : TAG NAME DIALOG BOX OPEN 0xA0F0 READ ONLY...
  • Page 38: Before Calling For Service

    Porch sound is likely to result from the cabinet lightly shrinking with the change of room temperature. The sound does not affect 640*480*60 25.175 - / - product’s performance. ORION Homepage Log on 800*600*60 40.002 1056 - / - 1024*768*60...
  • Page 39: Specification

    MLCD Infinitely Expandable www.oriondisplay.net Specification Regulatory Information Manufacturer's Name: ORION CO.,LTD. Product Name UNB Multi-LCD Monitor Manufacturer's Address 217, 1gongdan-ro, Gumi-si, Gyeongsangbuk-do, Korea D Model Name OLMU-K4650 OLMU-K4670 OLMU-K5550 OLMU-K5570 eclares that the products Model Numbers: OLMU-K5550 Manufacture SAMSUNG Conforms with the provisions of:...
  • Page 40: Dimension

    MLCD Infinitely Expandable www.oriondisplay.net Dimension 12.1.OLMU-K4650 / OLMU-K4670 12.2. OLMU-K5550 / OLMU-K5570 1213.4 100.5 100.8±2 1,022± 2 306.2 307.1 - 76- - 77 -...
  • Page 41 MLCD Infinitely Expandable www.oriondisplay.net MEMO MEMO - 78 - - 79-...

This manual is also suitable for:

Olmu-k5550Olmu-k4670Olmu-k5570

Table of Contents