Orion OPM-4260 User Manual

Orion OPM-4260 User Manual

Infinitely expandable mpdp
Hide thumbs Also See for OPM-4260:

Advertisement

MPDP
A revolutionary MPDP
Infinitely Expandable
A revolutionary MPDP
Infinitely Expandable MPDP
ORION CO., LTD.
www.oriondisplay.net
Address: 257-6, Gongdan-dong, Gumi-si, Gyeongsangbuk-do, Korea
Tel : +82-2-6678-8533,
Fax: +82-2-6678-8599
User's Manual
OPM-4260 | OPM-4260R
Thank you for purchasing our MPDP.
Please read through this user's manual for safety before installing this product.
This product is manufactured for Multi Plasma display model only.

Advertisement

Table of Contents
loading

Summary of Contents for Orion OPM-4260

  • Page 1 Address: 257-6, Gongdan-dong, Gumi-si, Gyeongsangbuk-do, Korea Tel : +82-2-6678-8533, Fax: +82-2-6678-8599 User’s Manual OPM-4260 | OPM-4260R Thank you for purchasing our MPDP. Please read through this user's manual for safety before installing this product. This product is manufactured for Multi Plasma display model only.
  • Page 2: Important Safety Instructions

    Features of MPDP Infinitely Expandable ▶  E njoy a wide flat screen with high brightness and high quality. ▶Easy to install and move due to its thin design ▶ E njoy your favorite programs with various split-screen features simultaneously presenting several programs.
  • Page 3: Table Of Contents

    2. WARNING - To reduce the risk of fire or electric shock, do not expose this appliance to rain or 5.15. Tracking Control .............................53 moisture. 5.16. ORION Homepage log on and Version Information ..................54 6. Control Method of optional accessory ....................55 3.
  • Page 4: C Autions For Consisting Mpdp System

    - When you design the exterior design for MPDP system, consider easier disassembly for possible service occasion in the future. - The sliding Universal Unit of ORION is recommended for easier service. - If service people can step into the backside of MPDP system, it can greatly reduce time and effort for service.
  • Page 5: Clearance For Ventilation

    1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. MPDP • Model Name : OPM-4260 • Voltage : AC~100 - 240V • Current : Max. 4A RS-232C •...
  • Page 6: Please Keep Following Instruction For Panel Protection Without Exception

    Infinitely Expandable OPM-4260 | OPM-4260R ※ Please keep following ※Handle with Caution. instruction for panel - Shock/Impact on the set's sides will result in internal protection without exception. circuit damages. Warning Warning - The edge/bottom of the panel are fragile.
  • Page 7 Infinitely Expandable OPM-4260 | OPM-4260R Open Structure How to carry MPDP Please see page 14 for unpack and handle assembly. Unlike consumer PDP product, the panel of MPDP is exposed without It always needs two persons to carry or install MPDP.
  • Page 8: Safety Precautions

    Infinitely Expandable OPM-4260 | OPM-4260R 1. Safety Precautions • If it operates abnormally, stop using it • Do not place any liquid-containing • Do not pull out or hang down the • Do not lean against the product or keep • Do not put any foreign material into...
  • Page 9: How To Install

    Infinitely Expandable OPM-4260 | OPM-4260R 2. How to Install • Install this set only at a location where adequate ventilation is available. How to assemble handles How to move MPDP 1. 2 people hold each handle on product's back side.
  • Page 10 Infinitely Expandable OPM-4260 | OPM-4260R MAIN FRAME Stand Unit (Option) MAIN FRAME Wall Mounting Unit (Option) • Please do not install our product at following locations to protect the product • Please check the stability of wall. and prevent possible malfunction.
  • Page 11: Guidance For Users

    2) This device must accept any interference received, including interference that may cause undesired operation. PWR ON MPDP CAUTION • Model Name : OPM-4260 RISK OF ELECTRIC SHOCK • Voltage : AC~100 - 240V RS-232C DO NOT OPEN • Current : Max. 4A To prevent electric shock, •...
  • Page 12: How To Connect Cables

    1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. MPDP • Model Name : OPM-4260 • Voltage : AC~100 - 240V RS-232C • Current : Max. 4A •...
  • Page 13: Connection Of Multiple Mpdp

    30 sets ORION Cable Only ※ It is highly recommended to use RS-232C cable provided by ORION.If you want to use the other RS-232C cable, it must be shielded. ※ Maximum use of RS-232C with Daisy Chain connection is 30 sets or less, if you need additional connection, use New MFC.(Max 30sets/1 port)
  • Page 14: Connection Of Control Cable - In Case Of Using Mscs

    Infinitely Expandable OPM-4260 | OPM-4260R 4.3. Connection of Control Cable - In case of using MSCS • Control signal transmission can be connected by 2 different methods. (RS-232C or Ethernet) • RS-232C and Ethernet connection cannot be used simultaneously. 4.3.2. Connection of Ethernet Cable 4.3.1.
  • Page 15: Connection Of Control Cable - In Case Of Using The Other Control Program Besides Mscs

    MSCS ※ If you use the other screen control program besides MSCS, the signal cable must be connected via MFC (Multi- Function Controller) of ORION. 4.4.2. Connection of Ethernet Cable • Control signal transmission can be connected by 2 different methods. (RS-232C or Ethernet) •...
  • Page 16: Connection Of Dvi Cable

    Infinitely Expandable OPM-4260 | OPM-4260R 4.5. Connection of DVI cable 4.6. Connection of optional accessory DVI-D DVI-D DVI-D RS-232C RS-232C RS-232C RS-232C DVI-D RS-232C DVI-D RS-232C DVI-D ID 1 ID 2 ID 3 ID 1 ID 2 ID 3 DVI-D...
  • Page 17: Id Setting Of X X Y Mpdp

    Infinitely Expandable OPM-4260 | OPM-4260R 5. Setting and operation of MSCS software 4.7. ID setting of X x Y MPDP [MPDP ID 01] 5.1. MSCS Installation • Identity number (ID) indicates the location of each MPDP. • Insert the Installation CD.
  • Page 18: Start Mscs

    Infinitely Expandable OPM-4260 | OPM-4260R 5.2. Start MSCS 5.3. Setting of COM Port • MSCS is an application program needed to control MPDP. • Com Port connects or disconnects the communication between PC and MPDP. • When you execute MSCS for your product at the installation screen, it will create a new folder •...
  • Page 19: Setting Of Lan Port (In Case Of Connecting To A Lan Hub)

    Infinitely Expandable OPM-4260 | OPM-4260R 5) Type in IP Address. 5.4. Setting of LAN Port (In case of connecting to a LAN Hub) • This function is used to control the MPDP via LAN PORT. * During the setting process, MPDP and control PC should be connected via RS-232C cable only.
  • Page 20: Setting Of Lan Port (In Case Of Connecting Directly To User's Computer)

    Infinitely Expandable OPM-4260 | OPM-4260R 5.5. Setting of LAN Port (In case of connecting directly to user's computer) n Check the network informations 5) Click "GET TCP/IP Info." and check the network informations. 1) Execute the LAN Configurator V1.0 from installation CD.
  • Page 21: New Design/Last Design" Setting

    Infinitely Expandable OPM-4260 | OPM-4260R 5.6. "New design/Last design" setting n Network IP setting for MSCS 1) Execute the MSCS. • You can see following pop-up window for "New design/Last design" when you click "Connect" or press "Ctrl+C" using keyboard after select communication type.
  • Page 22: Multi-Screen Configuration

    Infinitely Expandable OPM-4260 | OPM-4260R 5.9. Power On/Off 5.7. Multi-screen configuration 1) Power On: Press On button in the Power Mode. n Input the numbers of X and Y − X is for the number of row and Y is for column.
  • Page 23 Infinitely Expandable OPM-4260 | OPM-4260R C. Configuration Step 1) Select PDP set for Afterimage Mitigation Select ALL PDP or Broadcast for all PDP sets and One PDP for single PDP set. 2) Select the duration time in the Time Duration menu.
  • Page 24: Changing The Input Source

    Infinitely Expandable OPM-4260 | OPM-4260R 5.10. Changing the input source • Varieties of screen formations are available with screen configuration. • Select DVI, PC or Video at the Input Select menu. 5.10.2. Screen formation 5.10.1. If you select DVI and click Play button at the Input Select menu, the •...
  • Page 25: Slide Control

    Infinitely Expandable OPM-4260 | OPM-4260R 5.10.3. Screen Formation with one step. 5.11. Slide Control • You can make various multi-screen formations with simple movement. • MPDP configuration that users can choose is displayed repeatedly. • To use Slide Control, go to MSCS Menu -> Control -> Slide Control or press "Ctrl+S" using 1) Select an input source at Source Select menu.
  • Page 26 Infinitely Expandable OPM-4260 | OPM-4260R 3) Save various screen configurations in the same way. 6) Click "Stop" button to end "Slide Control" 4) Click "Slide Start" to display saved screen configurations. 7) Save or Load the slide configuration − Saved screen configurations are displaying for preset time.
  • Page 27: Picture Control

    Infinitely Expandable OPM-4260 | OPM-4260R 5.13. Timer Control 5.12. Picture Control • Users can decide the time of turning on or off MPDP set by timer control. • Register values related to display of MPDP can be changed. • To use this function, click Menu -> Control-> Timer Control or use 'Ctrl +M' keys from the •...
  • Page 28: Sync Control

    Infinitely Expandable OPM-4260 | OPM-4260R 5.14. Sync Control 5.15. Tracking Control • It reduces the flashing effect for MPDP. • Alignment adjustment is available when input source is PC. • Select Menu -> Control -> Sync Control or press “Ctrl + N”to execute Sync Control.
  • Page 29: Orion Homepage Log On And Version Information

    6. Control Method of optional accessory 5.16. ORION Homepage log on and Version Information 6.1. New MFC • In order to move to Orion website, go to "Help" of menu bar ->"OrionDisplay HomePage". (1) New MFC Connection 1) Connect power of New MFC 2) Connect female D-sub of New MFC to the Com port in the computer with RS-232C cable.
  • Page 30 Infinitely Expandable OPM-4260 | OPM-4260R (2) MPDP Set Configuration (e.g. X:5 sets x Y:6 sets) Vertical configuration 1. Press SET button. BROADCAST Horizontal configuration 1. Press SET button . DVI 1 BROADCAST DVI 2 2. Press Up and Down buttons sequentially to enter the vertical configuration mode.
  • Page 31: Dvi Converter

    Infinitely Expandable OPM-4260 | OPM-4260R 6.2. DVI Converter (1) ID • To use DVI Converter, go to MSCS Menu -> Device -> DVI Converter or press "Ctrl+V" using Keyboard. • Set the ID of DVI Converter. The ID can be selected from 1 to 9.
  • Page 32 Infinitely Expandable OPM-4260 | OPM-4260R (7) Key Lock Mode (4) Output Resolution • Lock the front key of DVI Converter not to turn On or Off. • Set the output resolution of DVI Converter. Resolution frequency 640 x 480 60Hz / 85Hz...
  • Page 33 Infinitely Expandable OPM-4260 | OPM-4260R (10) Pattern (9) Picture Control • Select the Test Pattern (Red, Blue, 8-Color, 16-Gray, Green, White, White (10%), Screen) • Control the Brightness, Contrast, Sharpness, Color, and Tint of the DVI Converter. • Set : Set or change the Pattern.
  • Page 34 Infinitely Expandable OPM-4260 | OPM-4260R (12) Tracking (13) PIP( Picture In Picture ) • Control the Screen size, sharpness, and position of DVI Converter for PC input mode. • A variety of images can be displayed with the PIP function of DVI converter. To activate PIP, click "PIP"...
  • Page 35: Mscs Protocol

    Infinitely Expandable OPM-4260 | OPM-4260R 7. MSCS Protocol 1. Introduction 2.2. Receive From PDP This chapter contains the communication protocol between PDP and its control devices such as computer for better use Length Data Check Sum of the product. However, it does not include detailed technical matters. It rather focuses on the brief functional explanation...
  • Page 36 Infinitely Expandable OPM-4260 | OPM-4260R 3.2. Power Off - Receive from MPDP Data Length Check Sum - Command for Power Off : Stand-by status Master - CMD : 0x41 Value 0x02 0x89 0x02 Variable Variable Variable 0x03 - It is available only during Power On (Operative) status.
  • Page 37 Infinitely Expandable OPM-4260 | OPM-4260R - Receive from MPDP 3.6. Input-Mode Change Data Length Check Sum - Command for changing input mode without screen scaling Master - It is available only on Power On (Operative) status. Value 0x02 Variable 0x02...
  • Page 38 Infinitely Expandable OPM-4260 | OPM-4260R 3.8. Auto-Power Mode 3.10. Over-Temperature Shut-down Control - Configuration for automatic power on by AC power connection. - Commands for automatic power off making MPDP set stand-by and OSD warning method, if IP board temperature is 95˚C or higher.
  • Page 39 Infinitely Expandable OPM-4260 | OPM-4260R - Receive from MPDP - Receive from MPDP Data Data Check Length Check Sum Length Master Master Value 0x02 Variable 0x02 Variable 0X01 Variable 0x03 Value 0x02 Variable 0x0A Variable 0x01 … Variable 0x03 * ID range (Program): 0x01(1) ~ 0xFF(255) * Check Sum: execute "Not"...
  • Page 40 Infinitely Expandable OPM-4260 | OPM-4260R Broadcast Command 54321 → 0x00 0x05 0x04 0x03 0x02 0x01 28~33 Elapsed Time 6 byte → 0x00 0x00 0x00 0x00 0x01 0x00 Data Length Default(No Display) : 0x00 Value Afterimage Mitigation 1 byte Full White...
  • Page 41 Infinitely Expandable OPM-4260 | OPM-4260R 3.18. Sync Correction Normal Command Data Length - It is the command for reducing the flashing effect. Master Value 0x02 Variable 0x02 Variable 0X01 0x03 1) Sync Correction Mode Broad-Cast Command - User can select or switch the Sync Control mode; “Auto” or “Manual.”...
  • Page 42 Infinitely Expandable OPM-4260 | OPM-4260R 3.19. White Balance Control Broadcast command Data - Command for adjusting Gain R/G/B and Offset R/G/B for White balance Length Control Data - CMD: 0xAC (Gain R), 0xAD (Gain G), 0xAE (Gain B), 0xB0 (Offset R), 0xB1 (Offset G), 0xB2 (Offset B)
  • Page 43 Infinitely Expandable OPM-4260 | OPM-4260R 3.21. Get Picture Control Data 3.22. Auto Calibration - Command for acquiring the current Picture Control Data(User Mode, White Balance, Graphic, Video) - Command for synchronizing the ADC Gain and Offset for 16-Gray input. It is available only for PC.
  • Page 44: Attachment : Ascii To Hex Conversion Table

    Infinitely Expandable OPM-4260 | OPM-4260R 8. Other tips 3.24. Get Temperature Status 8.1. Before calling for service - Command for acquiring temperature information. • Before calling for any repair, check the following and then refer to a near A/S center.
  • Page 45: About Plasma Display Panel

    Infinitely Expandable OPM-4260 | OPM-4260R 9. Applicable DVI signals 8.2. About Plasma display panel • When you select PC for input source, it does not support DTV signal. • The followings are phenomena caused by characteristics of the plasma display panel.
  • Page 46: Specification

    Infinitely Expandable OPM-4260 | OPM-4260R 10. Specification Model Name Model Name OPM-4260 OPM-4260R Power supply Power supply 100 ~ 240V AC. 50/60Hz 100 ~ 240V AC. 50/60Hz 330W 330W Power Power consumption consumption Average (Typical) 210W * Based on IEC 62087 Ed.2 measurement method.(On Mode)
  • Page 47: Option Specification

    Infinitely Expandable OPM-4260 | OPM-4260R 11. Option Specification 11.1. DVI Converter 11.2. New MFC Product Name Specification Product Name Specification Power supply 100 ~ 250V AC, 50/60Hz Name MPDP REMOTE CONTROL Power consumption 40W (MAX) Power 1.5V Battery(AAA) 2EA DVI Converter...
  • Page 48 Infinitely Expandable OPM-4260 | OPM-4260R MEMO MEMO - 92 - - 93 -...

This manual is also suitable for:

Opm-4260r

Table of Contents