7.3.5 OSD Control Command and Data
FUNCTION
MCMD
SCMD
INFORMATION OSD ON
0x0710
-
OSD ON/OFF TIME
0x0700
D1 : 0 ~ 60
D1 : 0~100 OSD Horizontal POSITION,
OSD POSITION
0x0701
D2 : 0~100 OSD Vertical POSITION
OSD TRANSPARENCY
0x0702
D1 : 0~10
OSD ROTATION
0x0703
D1 : 0~2, 0: 0°, 1: 90°, 2: 270°
D1 : 0~7, 0-ENGLISH, 1-DEUTSCH, 2-FRENCH,
OSD LANGUAGE
0x0720
7.3.6 E.T.C Control Command and Data
FUNCTION
MCMD
SCMD
FAN ON/OFF
0x07A0
D1 : 0x01-ON, 0x00-OFF
IR LOCK
0x0800
D1 : 0x01-ON, 0x00-OFF
Alert Message
0x0820
D1 : 0x00(DISABLE), 0x01(ENABLE)
DIALOG BOX OPEN
0x08F1
-
DIALOG BOX OPEN
D1-FAN ON/OFF,
0x08F1
(W/ MONITOR DATA)
D2-IR LOCK
- 72 -
DATA
REMARK
WRITE ONLY
WRITE ONLY
3-ESPANOLA, 4-NETHERLANDS, 5-POLISH,
6-RUSSIAN, 7-ITALIAN
DATA
REMARK
READ ONLY
RECEIVE ONLY
7.3.7 LAN Configuration Command and Data
FUNCTION
MCMD
SCMD
LAN ON/OFF
0x0750
GET TCP/IP
0x0760
SET TCP/IP
0x0761
RESET TCP/IP
0x07FE
DIALOG BOX OPEN
0x07F0
DIALOG BOX OPEN
(W/ MONITOR DATA)
0x07F0
7.3.8 Model Information Command and Data
FUNCTION
MCMD
SCMD
SET TAG NAME
0x0031
DIALOG BOX OPEN
0xA0F0
DIALOG BOX OPEN
0xA0F0
(W/ MONITOR DATA)
0xA0F1
DATA
REMARK
D1 : 0x01-ON, 0x00-OFF
D1~D4 : IP ADDRESS
READ ONLY
D5~D8 : SUBNET MASK
D9~D12 : GATEWAY
D13~D17 : DNS PORT NUMBER
D1~D4 : IP ADDRESS
D5~D8 : SUBNET MASK
D9~D12 : GATEWAY
D1~D4 : IP ADDRESS (192.168.0.2)
D5~D8 : SUBNET MASK (255.255.255.0)
D9~D12 : GATEWAY (192.168.0.1)
-
READ ONLY
D1-LAN ON/OFF
RECEIVE ONLY
D2~D5 : IP ADDRESS
D6~D9 : SUBNET MASK
D10~D13 : GATEWAY
D14~D18 : DNS PORT NUMBER
DATA
REMARK
D1~D16 : TAG NAME
-
READ ONLY
D1~D16 : MODEL NUMBER
RECEIVE ONLY
D17~D32 : TAG NAME
D1~D16 : FIRMWARE VERSION
RECEIVE ONLY
D17~D19 : MAC ADDRESS