PROTOCOL

■ Introduction
- This document contains the communication PROTOCOL between LCD and its control devices for better use.
- It focuses on the brief functional explanation and communication protocol without detailed technical matters.

7.1. Communication Setting

ITEM
TRANSMISSION & RECEPTION TYPE
CONNECTION TYPE
BAUD RATE
DATA BITS
PARITY
STOP BITS
FLOW CONTROL
CABLE & PIN ASSIGN
SPECIFICATION
ASYNCHRONOUS SERIAL COMMUNICATION
DAISY CHAIN
57600 bps
8
NONE
1
NONE
9PIN D-SUB, MALE / FEMALE STRAIT TYPE
PC
PIN NO.
PIN NO.
RX DATA
2
2
TX DATA
3
3
GND
5
5
- 68 -

7.2. Protocol Format

7.2.1 Send Protocol Format
STX
COMMAND
STX
MCMD
7.2.2 Receive Protocol Format
STX
COMMAND
STX
MCMD
* STX - 0x02, EXT - 0x03
7.2.3 Description of Protocol Format
ITEM
STX
MCMD
SCMD
LEN
LENGTH OF ID & DATA
GID
MID1
MONITOR ID (MSB)
MID2
MONITOR ID (LSB)
D1
Dn
MONITOR
CS
EXT
TX DATA
RX DATA
GND
LEN
DATA
SCMD
LEN
GID
MID1
MID2
D1
LEN
DATA
SCMD
LEN
GID
MID1
MID2
D1
DESCRIPTION
VALUE
SIZE
START OF CODE
0x02
1 BYTE
MAIN COMMAND
VARIABLE
1 BYTE
SUB COMMAND
VARIABLE
1 BYTE
VARIABLE
1 BYTE
GROUP ID
VARIABLE
1 BYTE
VARIABLE
1 BYTE
VARIABLE
1 BYTE
FIRST DATA
VARIABLE
1 BYTE
nTH DATA
VARIABLE
1 BYTE
CHECKSUM
VARIABLE
1 BYTE
END OF CODE
0x03
1 BYTE
- 69 -
EXT
...
Dn
EXT
CS
EXT
...
Dn
CS
EXT
REMARK
ID = 0 :
ALL MONITOR(BROADCAST)
DATA : n BYTE
SUM = "FF"