Protocol; Control; Communication Setting - Orion OLMU-K4953 User Manual

Infinitely expandable mlcd
Table of Contents

Advertisement

7.

PROTOCOL

■ Introduction
- This document contains the communication PROTOCOL between LCD and its control devices for better use.
- It focuses on the brief functional explanation and communication protocol without detailed technical matters.

7.1. Communication Setting

ITEM
TRANSMISSION & RECEPTION TYPE
CONNECTION TYPE
BAUD RATE
DATA BITS
PARITY
STOP BITS
FLOW CONTROL
CABLE & PIN ASSIGN
SPECIFICATION
ASYNCHRONOUS SERIAL COMMUNICATION
DAISY CHAIN
57600 bps
8
NONE
1
NONE
9PIN D-SUB, MALE / FEMALE STRAIT TYPE
PC
PIN NO.
PIN NO.
MONITOR
RX DATA
2
2
TX DATA
TX DATA
3
3
RX DATA
GND
5
5
- 70 -
7.2. Protocol Format
7.2.1 Send Protocol Format
STX
COMMAND
STX
MCMD
SCMD
7.2.2 Receive Protocol Format
STX
COMMAND
STX
MCMD
SCMD
* STX - 0x02, EXT - 0x03
7.2.3 Description of Protocol Format
ITEM
DESCRIPTION
STX
START OF CODE
MCMD
MAIN COMMAND
SCMD
SUB COMMAND
LEN
LENGTH OF ID & DATA
GID
MID1
MONITOR ID (MSB)
MID2
MONITOR ID (LSB)
D1
Dn
CS
EXT
END OF CODE
GND
LEN
DATA
LEN
GID
MID1
MID2
D1
LEN
DATA
LEN
GID
MID1
MID2
D1
VALUE
SIZE
0x02
1 BYTE
VARIABLE
1 BYTE
VARIABLE
1 BYTE
VARIABLE
1 BYTE
GROUP ID
VARIABLE
1 BYTE
VARIABLE
1 BYTE
VARIABLE
1 BYTE
FIRST DATA
VARIABLE
1 BYTE
nTH DATA
VARIABLE
1 BYTE
CHECKSUM
VARIABLE
1 BYTE
0x03
1 BYTE
- 71 -
EXT
...
Dn
EXT
CS
EXT
...
Dn
CS
EXT
REMARK
ID = 0 :
ALL MONITOR(BROADCAST)
DATA : n BYTE
SUM = "FF"