1. INSTALLATION
1.4

Settings

How to set the external equipment
Set the DIP switch S101 on the PANEL Board (05P0820) according to equipment connected. All
switches are in the OFF position in the factory setting. Set a switch in the ON position if the related
equipment is not connected.
1 No.1 VHF
2 No.2 VHF
3 MF/HF
4 No.1 INMARSAT ENABLE DISABLE
5 No.2 INMARSAT ENABLE DISABLE
6 NAVTEX
7 NAVTEX SEL
8
"SPARE" sticker
If you connect one Inmarsat C only, put the "SPARE" stickers on No.2 INMARSAT indications for
LED lamp and DISTRESS button. The "SPARE" stickers are attached on the reverse side of the
operation panel.
OFF
ON
ENABLE DISABLE
ENABLE DISABLE
ENABLE DISABLE
ENABLE DISABLE
NC
NO
DIP Switch
S101
#1-#6
ON: Equipment not connected.
OFF: Equipment connected.
#7
NX-700: OFF
NX-500: ON
8 7 6 5 4 3 2 1 O F F