1. INSTALLATION
Cable for external alarm (DPYC-1.5)
Armor
How to fasten a WAGO connector
Core
50
50
Sheath
30 30
Vinyl tape
Set this section in
cable clamp
Push
Terminal opener (located inside the equipment)
1. Twist conductors.
2. Set opener as shown and push down.
3. Set core to hole.
4. Release opener.
Twist.
5. Pull the core to be sure it is inserted correctly.
130
130
8 to 9
8 to 9
Core
Attach WAGO
connector
4