Caradon Plumbing Mira Elite 8.5 Installation, Operation, Maintenance Manual page 32

Pumped electric shower
Table of Contents

Advertisement

Malfunction
Shower cycles
on/off/on at high
temperature/low
flow.
Water will not
turn off.
With pull-cord
turned on
"Power" LED
is lit. LED then
goes out when
appliance is
turned on.
Temperature
knob will not
move fully from
blue bar to red
bar, resulting
in difficulty
in adjusting
to required
temperature.
32
a b
The temperature control
has been turned too far
clockwise. To protect
the appliance, a thermal
switch disconnects the
power to reduce the water
temperature. When it has
cooled down the power
is then re-applied. This
will cause the shower
temperature to increase
again.
Spray plate blocked.
 
Regulator flow switching
assembly faulty.
Neutral fault on supply cable. Locate fault and remedy.
Temperature control
knob replaced on splines
incorrectly.
cause
remedy
The temperature
control should be
turned anticlockwise
to increase the
flow, preventing the
operation of the
thermal switch.
Remove and
clean, following the
instructions contained
in the Installation,
Operation and
Maintenance Guide,
supplied with the
shower fittings.
Replace.
Refit temperature
control knob.
Refer to section
9, Maintenance:
"appliance control
knobs - refitting".