1.13. Bring the electrical supply cable
into the case via one of the cable
entry points, and offer up to the
terminal block. Cut the thinned
case areas as necessary.
1.14. Strip back approximately 40 mm of
the outer cable insulation.
Lift up the bottom of the dripshield
to access the terminal block
(there is no need to remove the
dripshield).
Note! DO NOT twist the individual
cable cores as this will prevent
them from entering the terminal
block.
Connect the conductors firmly into
the terminal block (refer to wiring
diagram). Fit an earth sleeve to the
earth conductor. Ensure that the
cable is clear of the cover when it
is refitted.