2.7. The appliance must be earthed by connecting the supply cable earth
conductor to the earth terminal. All exposed metal parts within 3 metres of
the shower, within the shower room, must be electrically bonded to earth
using a minimum cable size of 2.5 millimetres
2.8. Do not turn on the electrical supply until the plumbing has been completed,
and the pump primed, as the unit must not be operated dry (see Section 7,
Commissioning).
2.9. The appliance is fitted with a pump motor, and some mechanical noise can
be expected from the appliance in addition to the noise generated by the
spray from the handset. The type of wall surface will affect the perceived
sound levels. Stud partition and panel walls have a tendency to resonate,
whilst solid walls will provide the quietest operation. The tone of the pump
motor may change when the temperature control knob is adjusted. This is
quite normal.
Plumbing and electrical schematic Diagram
Cold Water Storage
Cistern (Tank)
Cold Water
Mains Feed
Cistern Fed
Cold Supply
to Other
Outlets
Hot Water
Cylinder Feed
Warning Pipe
Isolating
Valve
.
2
Independent Cold Water Supply
to Shower
Minimum
80 mm Head
Hot Water
Cylinder Vent
Pipe
Consumer Unit
Double Pole
Pullcord Switch
Hose Retaining
Ring