Caradon Plumbing Mira Elite 8.5 Installation, Operation, Maintenance Manual page 17

Pumped electric shower
Table of Contents

Advertisement

10 mm Minimum
100 mm Minimum
1.4. Slide out the case insert adjacent
to the 15 mm inlet compression
connector.
1.5. Determine whether the cold
water supply will be top (falling),
bottom (rising), or back inlet to
the appliance. Remove the inlet
blanking cap.
1.6. Swivel the 15 mm inlet
compression connector to suit.
Avoid trapping the green earth
bonding wire.
1.7. Remove as appropriate the thinned
case and cover areas to allow
the pipe and cable to enter the
product.
1.8. When deciding the position of the
appliance on the wall:
allow a minimum of 100 mm
clearance to the left-hand
side of the appliance case,
to provide unrestricted
access to the inlet connector,
for installation and future
maintenance.
allow a minimum of 10 mm
clearance from the top of the case
to allow the cover to be removed.
Offer the appliance up to the
wall and temporarily connect
the cistern-fed cold water supply
pipe. Mark through the casing the
position of the three fixing holes.
Remove the appliance.
17