Caradon Plumbing Mira Elite 8.5 Installation, Operation, Maintenance Manual page 11

Pumped electric shower
Table of Contents

Advertisement

1.4. We recommend that a non restrictive (free flowing) isolating valve is fitted
into the supply from the cold water cistern, for maintenance purposes.
1.5. The appliance must be fitted ONTO the finished wall surface i.e. on top of
the tiles. Do noT block the air ventilation gaps around the sides of the unit,
either by tiling up to the sides of the unit or by using a sealant around the
case. This appliance is designed to be ventilated. Failure to do this may
cause product failure.
1.6. Inlet: 15 mm inlet compression connector is designed to accept plumbing
supplies from the top, bottom or back.
1.7.
Back entry plumbing is accommodated without the need to recess the
15 mm inlet compression connector, enabling the wall's surface to be completed and
sealed to prevent water ingress, before final fitting.
1.8. Use only the 15 mm inlet compression connector supplied with the
appliance, do not use any other types of fitting.
1.9. Outlet: 1/2" BSP male, to accept Mira flexible hose.
1.10. Refrain from applying excessive force when making connections.
note! Excessive force on the pump housing can impair pumping
performance. Make sure that the supply pipe is trimmed and bent such that
the 15 mm inlet connector sits (or can be lightly pressed) easily on the back
of the clamp bracket prior to connection with the pump housing.
1.11. To avoid damage to the case when soldered fittings are used, pre-solder
the pipework and fittings before connecting them to the 15 mm inlet
compression connector.
1.12. Supply pipework MUST be flushed to clear debris before connecting the
appliance (Bye-law 55).
Small pillars moulded onto the back of the
case allow for air circulation
11