1.9. Install the cistern-fed cold water
supply pipe. An installation pipe
template is supplied (refer to
Appendix 5) and can be used so
the last 150 mm of the incoming
supply pipe can be bent to 17 °.
The 17 ° bend in the pipe ensures
that the supply pipe lies parallel to
the finished surface of the wall. It
also ensures that no stress is put
on the pump and clamp bracket.
For back inlet supplies, the cold
water supply pipe must emerge
from the walls surface 'square'
to prevent straining the inlet
connector clamp bracket.
1.10. Thoroughly flush the cistern-
fed cold water supply pipe. The
supply must be clean and free
from debris before connecting
the appliance (Bye-law 55).
1.11. Avoiding buried cables and pipes,
drill and suitably plug the three
fixing holes. Secure the appliance
to the wall with the screws
provided. Alternative fixings (not
supplied) may be necessary for
some wall structures.
1.12. Make the connection to the cistern-
fed cold water supply pipe. Hold a
wrench across the flats of the
15 mm inlet compression
connector to prevent damage to
the connector whilst tightening the
compression nut.