Caradon Plumbing Mira Elite 8.5 Installation, Operation, Maintenance Manual page 28

Pumped electric shower
Table of Contents

Advertisement

Malfunction
Appliance fails to
operate in any
switch position.
Shower
temperature
alternates hot
and cold.
Unable to select
a cool enough
shower (Summer
months only).
28
a b
Double-pole pullcord switch
turned off.
Supply fuse failed/RCD
tripped (which signals an
electrical fault).
The appliance is fitted with a
 
fixed temperature thermal
safety switch. Steady high
temperatures are thus
prevented.
The incoming cold water
supply temperature is often
higher than experienced
during the Winter.
cause
remedy
Switch on.
Contact a competent
electrician.
Turn the temperature
knob sufficiently
anticlockwise to
prevent operation of the
thermal switch. Allow
time for the
temperature
to stabilise. Do noT
tamper with the thermal
switch inside the
appliance.
Turn the control
knob to "low" power
setting and readjust
the temperature.