1
User instructions
Valve terminal type CPV...-GE-ASI-8E8A-Z-M8-CE has been
designed exclusively for controlling pneumatic actuators
and for use in bus systems in accordance with AS-Interface
specification 3.0. If used together with additional commer­
cially available components, such as sensors and actua­
tors, the specified limits for pressures, temperatures,
electrical data, torques etc. must be observed.
AS-Interface bus systems and valve terminals may only be
installed by personnel especially trained for this purpose.
Specifications on the design and addressing of your bus
system can be found in the manual for the AS-Interface
master.
Detailed information on the pneumatics of the valve ter­
minal can be found in the pneumatics manual P.BE-CPV-...
Warning
S Switch off the power supply before connecting or
disconnecting plugs (otherwise this could lead to
functional damage).
S Connect the earth connection on the left-hand end
plate with low impedance (short cable with large
cross-sectional area) to the earth potential.
S Commission only a valve terminal which has been
fitted and wired completely.