3.6 Connection example – valve terminal type 10
1
AS-Interface master
2
Combination power
supply from Festo
(electronically
safeguarded/
short-circuit proof )
3
Load voltage can
be switched off
3.7 Converting the valve terminal
The CPV valve terminal can be fitted with single-solenoid
valves and/or double-solenoid valves. For conversion, the
new valve terminal configuration must be set on DIP
switches on the bottom of the electrical sub-base.
1
DIP switch 1:
valve positions
1 to 4 (slave 1)
2
DIP switch 2:
valve positions
5 to 8 (slave 2)
Instructions on removing the electric sub-base can be
found in the pneumatics manual. The permitted valve
combinations as well as the relevant DIP switch settings
can be found in the table in section 3.3.