03

MANUAL OPERATION

3.1 Wi-Fi Configuration
This part shows the configuration using a web page.
Wi-Fi configuration is absolutely necessary for online monitoring and maintenance.
Preparation:
1. The inverter must be powered up with battery or grid power.
2. A router with internet access to the website
Step 1
1. Connect Solar-Wi-Fi* to your PC or smart phone (* its
name is the last 8 characters of the inverter's serial
number); Password: 12345678.
2. Open your browser and logon to 10.10.100.253
Admin (User): admin; Password: admin.
3. Then click "OK".
Step 2
1. Click "Start Setup" to choose your router.
2. Then click "Next".
Device information
Firmware version
1.6.9.3.38.2.1.38
19
MAC address
60:C5:A8:60:33:E1
Wireless AP mode
SSID
Solar-Wi-Fi
IP address
10.10.100.253
Wireless STA mode
Router SSID
WiFi_Bum-in
Encryption method
WAP/WAP2-PSK
Encryption algorithm
Router Password
WiFi_Bum-in
A "cannot join the network" error may be caused by:
No router, weak Wi-Fi signal, or the password is not correct
Help: The wizard will help you to complete setup
within one minute.
Start Setup
Please select your current wireless network
SSID
AUTH/ENCRY
RSSI
Wi-Fi_Burn-in
WPAPSKWPA2PSK/TKIPAES
66
Wi-Fi_Burn-in
WPAPSKWPA2PSK/TKIPAES
100
Wi-Fi_Burn-in
WPAPSKWPA2PSK/TKIPAES
70
Wi-Fi_Burn-in2
WPAPSKWPA2PSK/TKIPAES
72
Help: When the RSSI of the selected Wi-Fi network is below
15%, the connection may be unstable. Please select another
available network or decrease the distance between the
device and router. If your wireless router does not broadcast
its SSID, please click "Next" and manually add the wireless
network.
Back
www.semsportal.com
is required.
10.10.100.253
Admin(U):
admin
Password:
admin
Remember the password (R)
OK
Step 3
1. Fill in the password of the router, then click
"Next".
2. Click "Complete".
Add the wireless network manually
Enable
Wi-Fi-Test
Network name (SSID)
Encryption method
WPA/WPA2-PSK
Encryption algorithm
AES
Disable
Please enter the wireless network password:
Password (8-63 characters)
Router password
AES
Show psk
Note: The SSID and password are case sensitive. Please make
sure all parameters of the wireless network match those of the
router, including the password.
Back
Save success!
Click "Complete". the current configuration will take effect after
a restart.
Channel
If you still need to configure the other pages of information,
1
please proceed to complete your required configuration.
1
1
The configuration is complete. You can now log on to the
1
Management page to restart the device by clicking on the "OK"
Refresh
button.
Click Confirm to complete?
Back
Next
Note:
1. Please make sure the password and encryption method/algorithm are the same as those of the router.
2. If everything went well, the Wi-Fi LED on the inverter will change from a double blink to 4 blinks and then to a solid status, which means
that the Wi-Fi has successfully connected to the server.
3. Wi-Fi configuration can also be done on the PV Master App. For details, please check the PV Master App.
Wi-Fi Reset & Reload
A Wi-Fi reset means restarting the Wi-Fi module. The Wi-Fi settings will automatically be
reprocessed and saved. A Wi-Fi Reload means setting the Wi-Fi module to the default factory
settings.
Wi-Fi Reset Button
Wi-Fi reset
Quickly press the reset button.
The Wi-Fi LED will blink for a few
Cancel
seconds.
Note:
The Wi-Fi reset and reload functions are used only when:
1. Wi-Fi loses connection to the internet or cannot connect successfully to the PV Master App.
2. Cannot find the "Solar-Wi-Fi signal" or there are other Wi-Fi configuration problems.
3. Please do not use these buttons if Wi-Fi monitoring is working correctly.
4.If you need to replace the module,Please use the unlock tool

3.2 PV Master App

PV Master is an external monitoring/configuration application for hybrid inverters and is used on
smart phones or tablets for both Android and iOS operating systems. The main functions are
described below:
1. Edit the system configuration to make the system function as the customer requires.
2. Monitor and check the performance of the hybrid system.
3. Wi-Fi configuration.
Please download the PV Master App from the Google Play Store or Apple App Store. You can also
Next
download the App by scanning the QR code located on the back of this User Manual.
For the commission of the inverter please refer the PV Mastera App manual. Please download the PV
Master OPERATION INSTRUCTIONS from
www.goodwe.com

3.3 CEI Auto-Test Function

The PV auto-test function of CEI is integrated into the PV Master App to satisfy Italian safety requirements. For detailed instructions
regarding this function, please refer to "PV Master Operation Instructions".

3.4 Startup/shutdown Procedure

Complete
DC switch is used to cut off PV input power while the breaker equipped on the battery is used to cut off battery power.
When you want to shut down the inverter during an event, you should turn off the inverter DC switch and the battery DC breaker.
When you want to start-up the inverter after rectification, you should turn on the inverter DC switch and the battery DC breaker.
Wi-Fi
RESET
SYSTEM
BACK-UP
BATTERY
GRID
ENERGY
COM
Wi-Fi reload
Perform a long press of the reset button
(longer than 3 seconds).
The Wi-Fi LED will double blink until the
Wi-Fi is configured again.
Wi-Fi
FAULT
20
VIRGIN
4:21 PM
100%
95048EHU12345678
Waiting
0.00(kW)
0.00(kW)
0.00(kW)
0.00(kW)
Safety Country
English
Battery Type
Battery-Box H6.4
Operation Model
Normal
Meter Communication Status
CT connection
BMS Communication Status
Alarm warning
?
Backup Switch
On
Anti-Reverse Function Switch
Off