Simple Counting; Input Demand - Jadever JWI-3100 User Manual

Table of Contents

Advertisement

/G/N
2) Press
or
CAN DIEN TU TAN HIEP THANH
HOLD/LO/-
to change the value.
UNIT/SET
3) Press
ZERO/ESC
4) Press
Place the sample on the weighing pan.
HI indication appears, when the item on the weighing pan is greater than the upper limit
OK indication appears, when the item on the weighing pan is between upper and lower limits.
LO indication appears, when the item on the weighing pan is smaller than lower limit
Note: the item on the weighing pan should be more than or equal to 20e.

7-4 Simple Counting

UNIT/SET
1) Press key
/G/N
Press key
2)
+/PRINT/HI
3) Use key
0
2 0
5 0
1 00
2 00
4) Put the corresponding samples on the weighing pan, and then press key
"SAMP" is displayed momentarily before the display reverts to the sample size.
→ → → →
5
R emove the samples and put the load on, the scale calculates the amount of the load.
6
To go back to the normal weighing mode, remove the load and press key
the proper weighing unit.
Note:
1. The larger of the sample size, the more accurate unit weight.
2. Symbol " " points at "UW" when calculated unit weight is lower than 4/5 of scale division.
www.tanhiepthanh.com.vn
TARE/
to shift key leftwards or rightwards. Press
to turn on or turn off the weighing check
to confirm and save the lower limit value.
to select the unit "PCS" under the weighing mode.
the ex-factory default sample quantity (10 pcs) is displayed.
,
HOLD/LO/-
or
to choose the sampling amount. Available options are
5 00
1 000( pieces) .
JWI-3000
+/PRINT/HI
or
TARE /
UNIT/SET
to select
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents