Check Weighing - Jadever JWI-3100 User Manual

Table of Contents

Advertisement

3) Remove all items from the weighing pan, the screen displays the tare value.
CAN DIEN TU TAN HIEP THANH
4) To clear tare with an empty pan, press down key
Preset Tare
TARE/
1) Long press key
left-most digit blinking.
/G/N
2) Press key
HOLD/LO/-
to increase or decrease setting values. E.g. here we set the Preset Tare value
as 0.500kg.
ZERO/ESC
3) Press key
4) Put the load on the container, the scale will automatically deduct the value of the container
from the total value.
TARE/
5) Press
or key
cancelled.

7-3 Check Weighing

Use this mode to compare the weight of an item to Lower, and Upper limits. When the check
weighing mode is enabled, the " " indicator will turn on.
Upper limit setting
+/PRINT/HI
1) Long press key
digit blinking.
/G/N
2) Press
or
HOLD/LO/-
to change the value.
UNIT/SET
3) Press
ZERO/ESC
4) Press
Lower limit setting
-/HOLD/LO
1) Long press key
digit blinking.
www.tanhiepthanh.com.vn
for 3 seconds. The scale is now in Digital inputting mode with the
TARE/
or
to shift leftwards or rightwards. Press key
to save and return to weighing mode,
ZERO/ESC
with no load on the pan if the tare function is to be
. The scale is now in Digital inputting mode with the left-most
TARE/
to shift key leftwards or rightwards. Press
to turn on or off the weighing check
to confirm and save the upper limit value.
. The scale is now in Digital inputting mode with the left-most
TARE/
or key
JWI-3000
ZERO/ESC
.
+/PRINT/HI
+/PRINT/HI
or
or
12