Advertisement

..................................................................................... 1
1
.
..................................................................................
2
.
3-1 Specifications & Features...................................................................
3-2 Front Panel......................................................................................
3-2-1 Display.........................................................................................
3-2-2 Keyboard......................................................................................
3-3 Rear Panel......................................................................................
3-4 Power supply....................................................................................
4-1 Load cell connection..........................................................................
4-2 Assembly Description of Upright Pole....................................................
5
.
5-1 Maximum Weighing Capacity & Division Setting......................................
5-2 Function Setting...............................................................................
5-3Description of Parameter Values...........................................................
....................................................................................
7
.
7-1 Weighing.........................................................................................
7-2 Tare.......................................................................................................
7-3 Check Weighing...............................................................................
7-4 Simple Counting..............................................................................
Content
................................................................................
1
1
2
2
4
5
5
6
6
7
8
9
11
12
12
13
14
15
15

Advertisement

Table of Contents
loading

Summary of Contents for Jadever JWI-700D Series

  • Page 1: Table Of Contents

    Content …………………………………………………………………………. 1 Introduction ………………………………………………………………………. Precautions 3.Product Introduction 3-1 Specifications & Features…………………………………………………………. 3-2 Front Panel………………………………………………………………………….. 3-2-1 Display…………………………………………………………………………….. 3-2-2 Keyboard………………………………………………………………………….. 3-3 Rear Panel………………………………………………………………………….. 3-4 Power supply………………………………………………………………………... 4. Installation 4-1 Load cell connection……………………………………………………………….. 4-2 Assembly Description of Upright Pole……………………………………………. Setting Mode 5-1 Maximum Weighing Capacity & Division Setting……………………………….. 5-2 Function Setting…………………………………………………………………….
  • Page 2: Introduction

    1. Introduction This manual contains installation and operation instructions for the JWI-700D /700S Series weighing indicator. Please read the manual completely before installation and operation. 2. Precautions  Place the indicator on a flat and stable surface.  Verify that the input voltage and the plug type matches the local AC power supply, see 3-4. ...
  • Page 3: Front Panel

    Features  Power-saving design, with auto-shut off function  Backlit LCD display with prominent 30mm high digits  Up to 1/15000 resolution  Gross or net weight switchable  Low battery indication  Flexible unit switching: Kg, g, lb.oz, 台斤,pcs ...
  • Page 4 JWI-700S Low battery indication Tare or Preset Tare Indication Center of Zero Indication. The zeroing range is ±2﹪of scale capacity Auxiliary display (battery power, parameter, accumulated number of weighments) TARE Symbol “ ” points at “TARE” when the weight of the container is tared . Symbol “...
  • Page 5: Keyboard

    The weight on the weighing pan is smaller than lower limit but over 20e. (with LOW lamp on) Stable indication 3-2-2 Keyboard JWI-700D JWI-700S Short press steps through activated weighing units, release on desired one. 1. Displays gross and net weight by turns 2.
  • Page 6: Rear Panel

    1. Memory recall 2. Shift keys leftwards when inputting the value 1. Select the former record when checking the accumulation record 2. Print out when connect to the printer 3. During setting value, add 1 to the current value 4. Set the upper limit of the check weighing 1.
  • Page 7: Installation

    Low battery warning When “ ” appears in the upper left corner of the weight window, the battery requires to be changed 4. Installation 4-1 Load cell connection LOAD-CELL CONN Shield SIGNAL LOAD CELL CONNECTION SHIELD 4-2 Assembly Description of Upright Pole (1)Rod seat (2)Upright pole (3)Racket...
  • Page 8: Setting Mode

    → → → Step 3: Install the Indicator (4) on the bracket, with the bracket aligning with the bracket slot (8) of the indicator. Step 4: After connecting load cell connector to load cell port, the installation is completed. Note: Use the knob pole (7) to adjust the inclination angle of indicator and the screw (6) to adjust direction of the indicator.
  • Page 9: Function Setting

    M-/SET UNIT Method2: Press to free-set the resolution. Press to choose the weighing unit TARE/ +/PRINT/HI Press to shift key leftward or rightward. Press OLD/ +/PRINT/HI to change the value. When move to the right-most, press OLD/ M+/SAVE to move the decimal point. Press to save and return.
  • Page 10: 5-3Description Of Parameter Values

    5-3Description of Parameter Values Offset value Displays the offset value and the keypad testing can be conducted Backlight mode Off :No backlight Auto:Auto on with items greater than 9d placed on the weighing pan or any key is pressed. But auto off after N seconds (N=2s, 5s, 10s, 20s, ever) with no action It is always on when the weights over 9e Ever= On:...
  • Page 11 Hold function HoLd – 0:No hold function HoLd – 1:Hold the peak weighing value. Press any key to release HoLd – 2:Hold the weighing value after stable. Press any key to release HoLd – 3:Hold the weighing value after stable. Move away the articles to release OLD/ HoLd –...
  • Page 12: Calibration

    TARE ZERO always: Tare/Zero function acts by pressing down key even if it is not stable Power saving function on: Enable the power saving function off: Disable the power saving function Initialization to start initialization. After the window displays “ok”, M-/SET, M+/SAVE Press...
  • Page 13: Operation

    to complete. “ ”appears at the left bottom. to save. After the window displays “ ”, it will return to normal weighing M+/SAVE 6. Press mode. Operation 7-1 Weighing Begin with no load on the scale, the display reading zero. Place item(s) to be weighed on the scale.
  • Page 14: Check Weighing

    left-most digit blinking. TARE/ +/PRINT/HI 2. Press to move the key leftwards or rightwards; Press OLD/ to change the value. E.g. here we set the Preset Tare value as 0.500kg M+/SET 3. Press key to save and return to weighing mode. 4.
  • Page 15: Simple Counting

    OLD/ +/PRINT/HI rightwards; Press to change the value M-/SET 3. Press to enable / disable the check weighing function M+/SAVE 4. Press to save the Lower limit and return to weighing mode Place the sample on the weighing pan, if the sample weight is under the lower weight range while over 20d, the LOW lamp will light up.
  • Page 16: Accumulation, Accumulation Display And Accumulation Clear

    7-5 Accumulation, Accumulation Display and Accumulation clear Accumulation M+/SAVE Under the weighing mode, put the item on the weighing pan. Press key at the “ ”. “ ” appearance of is displayed momentarily before the display reverts to the weight of the item.

This manual is also suitable for:

Jwi-700s series

Table of Contents