Plc Diagnostics - CombiLift C3000CB Manual

Table of Contents

Advertisement

Combilift Ltd

5.14 PLC Diagnostics

The diagnostics function can be used to make sure all components are
working correctly.
Mode 1 – Joystick Function
Move Switch '1' to the 'ON' position
Neutral Position
Forward Position
Reverse Position
Left Position
Right Position
FORWARD
LEFT
NEUTRAL
REVERSE
If the joystick is working correctly each LED will only light with
the joystick in the corresponding position.
If the joystick is malfunctioning the LED corresponding to the
position will not light up.
C2500CB-OM-EN-11
No LED
LED 1
LED 2
LED 3
LED 4
RIGHT
Mode 2 – Proximity Sensor Function
Move Switch '2' to the 'ON' Position
Front Wheel 0 Degree Sensor
Rear Wheel 0 Degree Sensor
Carousel Sensor
Front Wheel 90 Degree Sensor –
Rear Wheel 90 Degree Sensor –
Proximity Sensors can be energised by switching from Forward
Mode to Sideward mode.
If a LED does not light it should be energised manually to rule out
the failure of the corresponding proximity sensor.
Once activated the LEDs will remain lit until the switch is reset to
the OFF position.
C2500-C3000CB O&S Manual
LED 1
LED 2
LED 3
LED 4
LED 5
5-20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C2500

Table of Contents