Design And Function; Overview - ABB Sensyflow FMT200-ECO2 Operating Instructions Manual

Thermal mass flowmeter
Hide thumbs Also See for Sensyflow FMT200-ECO2:
Table of Contents

Advertisement

Sensyflow FMT200-ECO2 THERMAL MASS FLOWMETER | OI/FMT200-ECO2-EN REV. H

2 Design and function

Overview

Figure 1: Sensor with different screw-in adapter (examples)
Design
Model
Measuring media
Measuring accuracy*
Permissible measuring medium temperature T
Permissible operating pressure
Process connections
Wetted materials
Power supply
IP rating
Communication
Outputs in serial production
Analog outputs
Digital output
Pulse / frequency output
Approvals and certificates
*
The stated measuring accuracy only applies under the calibration conditions in the stated measuring range.
Integral mount design
Sensyflow FMT200-ECO2
Air
Measuring error < ±3 % of measured value, repeatability < ±0.5 % of measured value
−25 to 50 °C (−13 to 122 °F)
medium
Standard: 10 × 102 kPa (10 bar abs.)
High-pressure version: 16 × 102 kPa (16 bar abs.)
Small flange adapter ISO-KF flange; screwed connection G ⅜ in, G ¾ in, G ½ in, G 1 in;
Legris hose adapter, Transair adapter
Aluminum, Hostadur, tinned Cu, glass
24 V DC, ±10 %
in accordance with EN 60529: IP 65
serial, V24 / RS232C
0 to 5 V DC, 0 to 10 V DC, 0/4 to 20 mA, min. / max. alarm
Yes
Yes
Available on abb.com/flow or on request
5

Advertisement

Table of Contents
loading