Custom Wiegand; Wiegand Protocol Description - CAMDEN CV-940-20 Series Installation Instructions Manual

Biometric keypad reader
Table of Contents

Advertisement

9.12 Custom WIEGAND

BioManager has defined Wiegand 26 and 34 bit as
standard options and other 3 Wiegand settings as
user definable.
• To setup custom Wiegand format
• Select Wiegand menu from Settings (Fig. 9.12 a)
• At Wiegand setup window select one from
customs Wiegand (Fig. 9.12 b)
• Set Wiegand parameter
• Click on Save button
Note: Wiegand settings are out of scope for common
end user. Please ask your installer to set the parameters
and do not change it later. (Fig. 9.12 c)
For more information please refer to BioManager
User Manual

10. WIEGAND Protocol Description

The data is sent over the lines DATA 0 for the logic "0"
and DATA 1 for the logic "1". Both lines use inverted
logic, meaning that a pulse low on DATA 0 indicates a "0"
and a pulse low on DATA 1 indicates a "1".When the lines
D0
D1
Data bit 0 = approximately 100 us (microseconds)
Data bit 1 = approximately 100 us (microseconds)
00
5V
0V
1 ms
100 us
5V
0V
Page 19 of 21
Fig. 9.12 a
Fig. 9.12 b
Fig. 9.12 c
are high, no data is being sent. Only 1 of the 2 lines
(DATA 0 / DATA 1 ) can pulse at the same time.
Example: data 0010....
1
Time between two data bits: approximately 1 ms
(millisecond). Both data lines (D0 and D1) are high.
CV-940-20 Series