What does the Zero (Ø) key do? ..........22 Data Log Lite and Data Log Pro ..........23 Information key ................ 24 List of Measurement Units ............27 Auto Off (Automatic shutoff) ..........28 User Manual for meriGauge Plus System 2 of 47 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
Page 3
9R479-D October 2018 Prepare the meriGauge Plus for storage ....... 28 Do not use the USB in hazardous locations ......28 Application ..................29 meriSuite CG and USB Drivers required ........ 29 Specifications ................30 Approvals .................. 30 Display Specifications .............. 31 Dimensional Specifications .............
Page 4
Register your product ............... 43 Find downloads and documents ..........43 For repair or calibration ............44 Troubleshooting checklist ............46 Meriam Contact Information ..........47 User Manual for meriGauge Plus System 4 of 47 GlobalTestSupply www. .com Find Quality Products Online at:...
Meriam or its affiliates. It is not possible for Meriam to identify all foreseeable uses or misuses, therefore all persons involved in commissioning, using, or maintaining this product must satisfy their self that each intended application is acceptable.
• Oven calibration. • Multipoint Meriam adjustment. User Calibration User calibration refers to any calibration done outside of Meriam with non-Meriam traceability. User calibration includes: Multipoint user calibration or adjustment. • User Manual for meriGauge Plus System 6 of 47 GlobalTestSupply www.
9R479-D October 2018 General warnings and cautions Preventing injury Failure to follow all instructions could result in injury: Read the entire manual before using the meriGauge Plus • System. • Understand the contents before using the meriGauge Plus System. Follow all safety warnings and instructions provided with this •...
Only use Intrinsically Safe gauges and sensors in hazardous • locations. Never use General Purpose gauges or sensors in hazardous • locations. User Manual for meriGauge Plus System 8 of 47 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
Page 9
MGP7000X shipped. • Component substitution may impair Intrinsic Safety. • Repairs must be made at Meriam to retain the Intrinsic Safety Certification. Service gauges only in a safe location. • Replace batteries only in a safe location. •...
Tighten to finger tight plus 1.5 turns to 3 turns using a 23 mm (7/8 in.) wrench. Remember: The gauge will face the same direction as the Meriam logo on the sensor. See the Meriam logo in the red circle in the figure below. Use only a wrench on the hex fitting Never rotate a meriSense sensor by turning the meriGauge Plus gauge.
Page 11
Not recommended for continuous use • below 0.02 psi absolute. User Manual for meriGauge Plus System 14 of 47 GlobalTestSupply www. .com Find Quality Products Online at:...
Page 12
0 % to 110 % of Range: ± (0.02 % of Full Scale) + 0 % to 110 % of Range: (0.005 % of Reading) Vacuum*: ± (0.02 % of Full Scale) *Vacuum = –14.5 psi User Manual for meriGauge Plus System 15 of 47...
Page 13
Overrange limit Overrange pressure means the value is outside the calibrated upper or lower range. Up to 110 % of range, meriGauge Plus displays the accurate • pressure. • Above 110 %, it flashes red. This indicates that the applied pressure exceeds the calibrated range.
9R479-D October 2018 Gauge Batteries Know your batteries A list of batteries for the meriGauge Plus that have been approved (Intrinsically Safe) for use in Hazardous Locations. No substitutions are allowed. Duracell MN1500 • Duracell PC1500 • Energizer EN91 •...
Page 15
Visit the website of the battery manufacturer to learn more about the care, storage, shipping, use, disposal, and recycling of your batteries. Consider inserting new batteries Before you begin data logging or running a Rate of Change. User Manual for meriGauge Plus System 18 of 47 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
9R479-D October 2018 Connect the gauge to a sensor The gauge will face the same direction as the Meriam logo on • the sensor. See the circled Meriam logo in the figure below. With the sensor already installed in your process, slide the •...
% of Full Scale. Note: When you press the Information key, the bar graph displays the remaining state of the charge for the batteries. User Manual for meriGauge Plus System 20 of 47 GlobalTestSupply www.
10. DATA LOG (Data Log Release) 5. –RV (Relief Valve Test - 11. Time & Temperature Reseat) 6. + / - (Accuracy) User Manual for meriGauge Plus System 21 of 47 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
Demand type. Holding the Zero key The key must be held to perform the Zero or Tare mode. The displayed value(s) dashes out during the zero or tare process. User Manual for meriGauge Plus System 22 of 47 GlobalTestSupply www.
3. —COMPLETE—appears after one hour. Note: Auto Off is suspended during data logging. If you selected 5 Minutes for Auto Off, then meriGauge Plus remains on 5 minutes after data logging completes, and then turns off. Stop the data logging process...
October 2018 Information key Where is the Information key on the meriGauge Plus? The Information key is the red triangle in the Meriam logo. What does the Information key normally display on the meriGauge Plus? BATT % displays the percentage on the bar graph and in digits •...
Page 22
• TYP. DEMAND refers to On Demand. Note: See the Parameter Choices section in the meriSuite CG User Manual 9R609 for a description of the data log types. User Manual for meriGauge Plus System 25 of 47 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
Page 23
When the duration is set for Minutes, Hours, Days, or Points, • then the point number counts down to zero. When the point number reaches zero, the gauge displays • --COMPLETED--. User Manual for meriGauge Plus System 26 of 47 GlobalTestSupply www. .com Find Quality Products Online at:...
The meriSuite CG app gives you the ability to configure • specific measurement units to specific sensors. The meriGauge Plus displays only the units selected in • meriSuite CG for individual sensors. When the meriSense pressure sensors are shipped, the •...
Prepare the meriGauge Plus for storage Remove the batteries to store the gauge 1. Remove the batteries from the meriGauge Plus to store it for 30 days or more. 2. Follow the battery manufacturer’s instructions for storing your batteries.
1. Read the meriSuite CG User Manual. Note: You are now ready to use the meriSuite CG app to configure, to view data, and to create reports for the meriGauge Plus System. User Manual for meriGauge Plus System 29 of 47 GlobalTestSupply www.
Pi = 1.249W, Ii = 227mA, Ci = 30 μF, Li=0 μH, Ui = 5.5VDC CE Compliance MGP7000 and MS700 (General Purpose models) CE Compliance User Manual for meriGauge Plus System 30 of 47 GlobalTestSupply www. .com Find Quality Products Online at:...
9R479-D October 2018 Display Specifications Display rate The meriGauge Plus displays five (5) updates per second. LCD Display • The LCD displays six (6) digits. • The numerical display height is 17.8 mm (0.7 in.) Dimensional Specifications The meriGauge Plus gauge...
9R479-D October 2018 Material specifications meriGauge Plus aluminum housing The meriGauge Plus housing is made of these two types of aluminum: A356 Aluminum. • 6061 Aluminum. • Disclaimer: Special condition for the aluminum case Rare incidents: The case is made of aluminum. If you mount it in a...
9R479-D October 2018 Safety Hazardous locations use Intrinsically Safe Model The meriGauge Plus MGP7000X and meriSense MS700X include certification for Intrinsically Safe operation. Refer to the Intrinsic Safety Control Drawing for meriGauge 9R525 and for meriSense 9R526 in the Safety section in this manual for more information.
9R479-D October 2018 Intrinsic Safety Control Drawing for the meriGauge Plus gauge 9R525 User Manual for meriGauge Plus System 34 of 47 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
9R479-D October 2018 Intrinsic Safety Control Drawing for the meriSense sensors 9R526 User Manual for meriGauge Plus System 35 of 47 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
Keep the dust cap on sensors Make sure you put the dust cap on the sensor after the • meriGauge Plus gauge has been detached from the sensor. The dust cap protects both the electrical contacts and the vent. •...
Waste from Electrical and Electronic Equipment 2012/19/EU Note: The following marking indicates that you must not discard this electrical / electronic product in domestic household waste. User Manual for meriGauge Plus System 41 of 47 GlobalTestSupply www. .com Find Quality Products Online at:...
USB A to right angle mini B –3 ft black cable Z9P1055-2 Protective Boot Z9A1354 Hard carrying case Z9A878 “AA” Battery kit (4 pack) Z9P1641 Activation Key for Data Log Pro User Manual for meriGauge Plus System 42 of 47 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
Page 40
Option 3: Call Meriam to request repair or calibration. Before you ship anything to Meriam 1. You must receive a RMA number from Meriam first. 2. Clearly write on the package or place a shipping label on it with the RMA number (Return Material Authorization Number).
Page 41
Remember: The gauge will face the same direction as the Meriam logo on the sensor. (You may hear it click when it locks in place.) See the Meriam logo in the red circle in the figure below. Note: The locking pin prevents the gauge from accidentally disconnecting from the sensor.
Need help?
Do you have a question about the meriGauge Plus and is the answer not in the manual?
Questions and answers