Bulk Cable Specifications
•
Two twisted pairs, AWG 24, 120 ohm.
•
Shielding on each twisted pair, plus overall shielding.
•
1500V over-voltage minimum between signal wires and shielding.
•
Shielding connected on connector shell of P1 but not connected at P2.
•
Maximum length 30 m.
Connector P2
•
Not predefined. Depends on the customer equipment.
•
ETSI 300-11 standard.
Note:
If a cable not supplied by IBM is used, IBM does not guarantee
electromagnetic compatibility (EMC) compliance for the 82165 machine.
Cable List
Table 57. E1 Twisted Pair Cables
Length
m (ft)
Feature Code
15 (50)
30 (100)
70 (230)
100 (328)
122 (400)
Homologation and Notes
E1 twisted pair complies with the following EU directives:
EMC
LVD
Telecommunications
If the PTT require an ISO/IEC 10173 plug to connect the E1 daughter card, then the
IBM Service Engineer installs this plug on the fly-leads of the supplied cable.
World Wide Except
Germany
5260
57G8029
5261
57G8030
5262
57G8031
5263
57G8032
5264
57G8033
89/336/EEC
73/23/EEC
91/263/EEC
Appendix A. Connectors, Cables, and Accessories
Part Number
Germany
80G3983
80G3984
80G3985
80G3986
80G3987
87