Wan 2 Module E3/Ds3 Coax Cables And Connectors; Table 60. E3/Ds3 Cabling Details (Bnc 75 Ohm); Table 61. E3/Ds3 Cabling Distances - IBM 8265 Site Preparation Manual

Nways atm switch
Hide thumbs Also See for 8265:
Table of Contents

Advertisement

WAN 2 Module E3/DS3 Coax Cables and Connectors

90
IBM 8265: Planning and Site Preparation Guide
The media for both E3 and DS3 daughter cards is a 75 ohm impedance coaxial pair
with BNC connectors for each direction of transmission.
Cabling Information

Table 60. E3/DS3 Cabling Details (BNC 75 ohm)

Cable Type
Impedance
RG59
75 ohm
Note:
the 25 dB attenuation @ 400 MHz corresponds to an attenuation of
12 dB @ 17 MHz, assuming that follows approximately a
Cabling Distances
Because the maximum recommended distance depends on the quality of cabling
used, the values given in are approximate.

Table 61. E3/DS3 Cabling Distances

I/O Card Type
Cable Type
E3
RG59 coax
DS3
RG59 coax
Attenuation @ 400 MHz
25 dB MAX / 100 m
Maximum Recommended Distance
100 m (330 ft) based on a power budget of 12 dB
@ 17 MHz.
68 m (225 ft) default, 135 m (450 ft).
If cable distance exceeds 68 m (225 ft), the default
configuration setting for the port must be changed.
See the Media Module Reference Guide for details
on how to do this).
f
law.