Troubleshooting - Carbon Zapp CRU.4R Operation Manual

Table of Contents

Advertisement

Operation Manual – "R" Units

Troubleshooting

Component
PC
Pressure
Injection
Problem
Not Booting
Touch not working
Cannot Reach TP Pressure
Pressure on the screen gauge is
erratic, and no actual pressure is
present
Injector not injecting
Short Circuit / Open Circuit /
Short to Ground
Solution
Reboot the system (power on/off)
The Software is in DEMO Mode.
Reconnect Power to the machine /
Check USB Connection
EUI Proximity sensor is not
connected / Damaged
Wrong Injector Profile Selected:
Select Correct Component
Cable Damaged: Replace Cable
Injector Damaged
55
Assure Machine is plugged
in a power source and
turned on.
Switch the unit on/off
Assure there is enough
liquid in the tanks
Assure there is enough
Compressed air going into
the machine.
Assure the hydraulic system
is free of air (Degassed)
Use the Provided Plug to
eliminate a failing injector
factor. If the pressure
cannot be reached again
contact your service
provider.

Hide quick links: