Motion Control Damper Replacement

Note: There is a right and left motion control
damper. The following removal and installa­
tion procedures are on the left damper. The
procedure is the same for the right damper.

Motion Control Damper Removal

1. Park the machine on a level surface, disengage the
PTO, turn the ignition OFF and remove the key.
2. Remove the nut securing the damper ball joint to the
frame.
Note: You will need a T­40 Torx wrench to hold the
bolt while removing (Fig. 182).
Fig. 182
Toro Z Master G3 3000/5000/6000 Series Service Manual
3. Remove the nut securing the damper to the motion
control assembly (Fig. 183).
4. Remove the damper assembly (Fig. 184).
DSCN-4445a
CHASSIS
Fig. 183
DSCN-4448a
Fig. 184
DSCN-4450a