TECHNICAL DATA

3.1. Air conditioning system

Designation
Dimensions (rooftop air-conditioning unit)
Length x width x height
Weight
Operating voltage
(acc. to vehicle's electr. system)
Current consumption
Total current consumption
– Compressor motor
– Condenser fan
Switching points, low-pressure switch
– On
– Off
Switching points, high-pressure switch
– Off
– On
Rated power
at temperature inside 25°C and
at temperature outside 29°C
Refrigerant
Citysphere S
1200 mm x 860 mm x 250 mm
ca. 37 kg
24 V DC
65 A (max.)
55 A
10 A
2.1 ± 0.3 bar
2.0 ± 0.2 bar
26.5 ± 2 bar
20 ± 2 bar
3.8 kW
R134a, 1100g (already prefilled)

3.2. Electrical fuses

Protected components
Fuse
Letter symbol
Condenser fan
F1
Compressor
F5

3.3. Compressor Scroll 036cc

Lubricating oil for refrigerating compressors
(type / quantity)
Speed (const. speed via ON-signal)
For wiring diagram, refer to Installation Instructions.
TECHNICAL DATA
Fuse ratings
15A
60A
POE RL68H / 220 ml
2800 U/min
NOTE
25