Technical Specification - Valeo Aerosphere World Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Aerosphere World / Midibus
5

Technical Specification

The following Fig. lists the leading particulars of both air conditions systems and their variants.
Max. cooling capacity (in kW)
Cooling capacity (in kW)
(t
= 27 °C, t
= 35 °C)*
ev
amb
Heating capacity (in kW)
Height (mm)
Weight (kg)
Control system
Air volume (free, in m³ / h)
Fresh air (F)
Mix air (M) adjustable
Recirculation air (R)
Compressor type
Compressor oil type
Compressor oil volume
Refrigerant type
Refrigerant charge
Refrigerant charge with frontbox
High pressure switch (bar)
Low pressure switch (bar)
Number of evaporator blowers
Number of condenser fan
* t
= temperature evaporator
ev
T
= temperature e ambient
amb
40
Aerosphere World
short version
32
35
24
30
38
32
210
210
200
230
6300
100 %
Bock FKX40/560-K
Bitzer 4PFC-558 cm³
2.0 l
8.5 kg
9.5 kg
6
4
Fig. 9 Technical Data
long version
39
34
32
210
230
Globus
8400
50 / 50 %
100 %
Bock FKX40/650-K
Bitzer 4NFC-647cm³
Triton SE55
R134a
9.0 kg
10.0 kg
aus: > 25 ±1 bar
; ein < 19 ±1 bar
abs
aus: < 1.3 ±0.3 bar
; ein > 2.8 ±0.3 bar
abs
8
5
Midibus
25
21
18
14
27
27
220
220
135
130
4200
90 %
Bock FKX40/390
TM-31
Bitzer F400
Unicla UX330
PAG
2.0 l (Bock)
0.8 l
1.0 l (Bitzer)
6.5 kg
7.5 kg
abs
abs
4
3
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Midibus