Mr3 Lens Uv-Light Retrieval - Ultra Optics MR3 Standard Operating Procedure

Coating machine
Table of Contents

Advertisement

MR3 Lens Retrieval From UV
Light Module
Detach remaining lenses off of the suction cups.
Turn off the power to the machine and disconnect the power cord
from the electrical outlet.
With the power off, open the back doors of the machine.
Remove the screws that hold the UV light module in the carriage.
Remove the UV light module by grabbing the silver handle and
pulling it straight out.
Allow UV light to cool for 15 minutes or until it reaches room
temperature.
Remove the lens from the lamp and reflector area. Be careful not
to touch the UV bulb.
Check the bulb and reflectors for any melted lens debris or
burns. If debris or burns are present and can not be cleaned,
replace the UV light module with a new one.
If original lamp looks clean or is able to be cleaned, return it to
the carriage and reinstall the screws. (for cleaning
recommendations please contact a UOC technician)
Plug in the power cord, turn machine on, and return to normal
machine operation after the warm up process is complete.