Flushing The Coating System - Ultra Optics MR3 Standard Operating Procedure

Coating machine
Table of Contents

Advertisement

Flushing Coating System
Always wear approved Nitrile gloves
when performing the coating flush.
Press MACHINE SET-UP.
Press COATING PRIME.
Press VACUUM button.
Chuck a lens on the suction cup over the
coating bowl.
Position clean container under the filter.
Disconnect the nut from the nylon elbow at
the bottom of the coating filter.
Point nut and tubing into clean container.
Press COATING ON/OFF button.
The coating will flow out of the tubing into
the container.
When reservoir is empty press COATING
ON/OFF button to turn off coating pump.
19