INFORMATION LEVELS:
Basic information level
I
Press the
key to enter the basic information le-
I
vel. Press the
again to scroll through the va-
lues listed below .
(*)The DHW key above the display.
Functioning phases (table 1)
Nr. displayed
00
Standby
01
Ignition prevented
02
Fan start
03
Pre-ventilation
04
Wait time
05
Pre-ignition time
06
Safety time, constant
07
Safety time, variable
10
Central heating mode
11
Domestic hot water mode
12
Simultaneous CH and dHW mode
Post-ventilation with last control
20
used
Post-ventilation at pre-ventilation
21
level
22
Home run (*)
99
Burner lockout (error code displayed)
(*)Home run = Boiler status after reset.
EXTENDED INFORMATION LEVEL 1: temperatures
I
Press the
key .
D U
Press and hold both
conds .
+ -
Press one of the
quired parameter .
M
V
Press
or
screen .
Temperatures
b0
Control board error code
b1
Boiler return temperature
b2
Not used
b3
Flue gas temperature
b4
Outdoor temperature
b5
Compound outdoor temperature
b6
Attenuated outdoor temperature
b7
Not used
b8
Reserved
b9
Reserved
Description
keys for at least 3 se-
keys until you reach the re-
to return to the main
Description
Key
v
DHW temperature
t
t
Water pressure (NOT USED)
t
t
X.
Functioning phase (see table 1)
c
Outdoor temperature
(Accessory) controller error codes
Ex
(see the "Error codes and malfun-
ctions" section)
r
Boiler temperature
(*) Press one of these keys to return
M V
to the main screen.
9
ENd USER