SRM-6 Operation & Diagnostics

Channel Alarm Mask Configuration Screens

At the SRM-6 Configuration menu, press 4 and then press Enter to configure alarms on
channels 1 through 6. The Channel Alarm Configuration screen, shown below, illustrates the
selections for Channel 1.
Table 3-5
Channel Alarm Configuration Selections
Selection
[1] through [9]
and
[A] through [C]
[D]
[CR]
[S]
[0]
Special Considerations
Masks set at the Channel Interface Alarm Mask Configuration screen are applied to alarm events
displayed at the Alarm Monitor screen. However, the Interface Status screen will always show the
status of all interface signals without masking.
When alarm conditions are set as Reported and the alarm is active, the SRM-6 will send a trap via
the SCM.
3-6
Table 3-5
describes the screen selections, with defaults shown in Bold.
Items
Description
No Remote CTS
For the selected channel interface, sets the No Remote CTS
alarm as a
No RTS
For the selected channel interface, sets the No RTS alarm as
a
Masked
All Alarms Control
Globally selects all channel interface alarms as Masked or
Reported; Mixed is a read-only status.
Return to Previous Menu Returns to the SRM-6 Configuration screen without saving
channel alarm configuration changes to the unit.
Save
Saves channel alarm configuration changes to the unit.
Return to Main Menu
Exits the Configuration menu and returns to the SRM-6 Main
Menu.
SC SRM-6 Multiplexer
Installation & Operation Manual
SRM-6 Configuration Menu
Masked
or Reported alarm.
or Reported alarm.
076R176-000
Issue 1