Channel Interface Configuration Screen - General DataComm SpectraComm SRM-6 Installation & Operation Manual

Subrate multiplexer
Table of Contents

Advertisement

SRM-6 Operation & Diagnostics

Channel Interface Configuration Screen

At the SRM-6 Configuration menu, press 2 and then press Enter to access the Channel
Interface Configuration screen, shown below.
defaults shown in Bold.
Table 3-3
Channel Interface Configuration Selections
Selection
[1] Channel Number
[2] Channel Enable/Disable
[3] Channel Rate
[4] Mode of Operation
[5] Async Character Length
[6] TX Data Clock
[7] CTS Control
[CR] Return to Previous Menu
[S] Save
[0] Return to Main Menu
Special Considerations
Channel DCD will turn ON when Aggregate DCD is ON.
Overspeed is 1% (nominal) for asynchronous operation.
Channel DSR is always forced ON.
3-4
Table 3-3
SRM-6 Channel Interface Configuration
[1] Channel Number
[2] Channel Enable/Disable:Enable
[3] Channel Rate
[4] Mode of Operation
[5] Async Character Length:10 bits
[6] TX Data Clock
[7] CTS Control
[CR] Return to Previous Menu
[0]
Return to Main Menu
Select: [ ]
Selects a channel: 1 through 6.
Disable
Enable/
Sets the rate for the selected channel:
1200 bps,
2400 bps
(Note: In 56/64 Kbps operation, 1200 bps is not available.)
Sets asynchronous or
channel.
Sets the async character length for the selected channel as: 8 bits, 9
bits,
10 bits
Sets the TX Data Clock for:
ST
(DCE Send Timing), or
TT (DTE Terminal Timing)
Sets the CTS action for the selected channel as:
Follows RTS (CTS follows RTS), or
Forced ON
(Force CTS ON)
Returns to the SRM-6 Configuration screen without saving channel
interface configuration changes to the unit.
Saves channel interface configuration changes to the unit.
Exits the Configuration menu and returns to the SRM-6 Main Menu.
SC SRM-6 Multiplexer
Installation & Operation Manual
SRM-6 Configuration Menu
describes the screen selections, with
:1
:9600 bps
:Sync
:ST
:Forced On
[S] Save
Description
the channel for sending/receiving data.
, 4800 bps, 9600 bps, or 19200 bps
synchronous
operation for the selected
, or 11 bits (includes Data, Start, Stop, and Parity bits)
076R176-000
Issue 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

076p054-001