Aggregate Alarm Configuration Screen

At the SRM-6 Configuration menu, press 3 and then press Enter to access the Aggregate Alarm
Configuration screen, shown below.
in Bold.
Table 3-4
Aggregate Alarm Configuration Selections
Selection
[1] No Frame Sync
[2] No DCD
[3] No Remote Frame Sync
[4] All Alarms Control
[CR] Return to Previous Menu
[S] Save
[0] Return to Main Menu
Special Considerations
Masks set at the Aggregate Alarm Configuration screen are applied to alarm events displayed at the
Alarm Monitor screen. However, the Interface Status screen will always show the status of all
interface signals without masking.
When alarm conditions are set as Reported and the alarm is active, the SRM-6 will send a trap via
the SCM.
076R176-000
Issue 1
Table 3-4
describes the screen selections, with defaults shown
SRM-6 Aggregate Alarm Configuration
Aggregate Interface Alarm Masks
[1] No Frame Sync
[2] No DCD
[3] No Remote Frame Sync
[4] All Alarms Control
[0] Return to Main Menu
[CR]Return to Previous Menu
Select: [ ]
For the aggregate interface, sets the No Frame Sync alarm as a
Masked
or Reported alarm.
For the aggregate interface, sets the No DCD alarm as a
Reported alarm.
For the remote aggregate interface, sets the No Remote Frame Sync
Masked
alarm as a
Globally selects all aggregate interface alarms as Masked or Reported.
Returns to the SRM-6 Configuration screen without saving aggregate
alarm configuration changes to the unit.
Saves aggregate alarm configuration changes to the unit.
Exits the Configuration menu and returns to the SRM-6 Main Menu.
SC SRM-6 Multiplexer
Installation & Operation Manual
SRM-6 Configuration Menu
: Reported
: Masked
: Masked
: Masked
[S] Save
Description
or Reported alarm.
Masked
or
3-5