Command Reference Setup Level - Measurement Computing DPG Series Instruction Manual

Inclinometer
Table of Contents

Advertisement

Instruction Manual
6.2.2

Command Reference SETUP level

Setup level will be used for permanent settings, stored.
Commands in
setup level
Stop continuous
output of inclination
values
Start continuous
output of values
Set zero
Setback zero
Set lowpass filter
Set output rate
Show internal
settings
Show currently
temperature [°C]
Software reset
Erase both Info
segments,
(switch to default
settings)
Forbidden command
MEAS Deutschland GmbH
Hauert 13, D-44227 Dortmund, Germany
DPG-Series Inclinometer
Input
Output
"c"
"c"
"C"
"N"
"N"
"n"
"n"
"M",
"M",
f
f
"O",
"O",
o
o
"
"
*
"O123 M123", CR, LF
"OffX=+00.000
OffY=+00.000", CR, LF
"Erase Cycl SegF:
+00255", CR, LF
"T"
"T= 00.00", CR,LF
"q"
"q"
"E"
"Seg A deleted" , CR, LF
"Seg B deleted" , CR, LF
"#"
"#"
www.meas-spec.com
Comment
This level will be terminated (reset)
automatically after about 10 minutes of
user inactivity.
Stops the continuous output of angle
results or raw values, required for input
of commands, terminated by "C",
mode permanent,
query with " R", see chapter 6.2.1.
Start the continuous output of angle
results or raw values,
mode permanent, valid after reset.
Define 0° position. Offset is stored and
used even after reset.
Resets the offset displacement
Input filter settings with count
f = "0"..."7", other characters were
answered with "E", see item 1) below.
Set output rate with count o = "1"..."6",
other characters were answered with
"E", see item 2) below.
"O123": internal setting of output rate in
10ms, "M123": internal filter setting;
both values 255 => default settings
"Off..": stored Offset values
"Erase Cycl Seg...": active Segment
and number of erasure procedures for
this segment
Readout the currently temperature in
°C. Usable at > software version 2.0.2.
Without sign, positive temperature.
With sign `- `, negative temperature.
Reset the sensor
Erases the info segments of flash
storage banks, InfoA and InfoB. This
set all changed user values to default
settings
Reserved for factory communication
12 of 15
July 2015