C85 / C95 non-metallic Control Panel Timer
TIME CLOCK SETTING
To set the current time, turn the inner dial clockwise. Do not set the time by rotating "outer" dial. Turn the minute hand or small
plastic inner dial clockwise until the time of day on the outer dial is aligned with the triangle marker on the inner dial (two o'clock
position). Example for 10:00 AM: Turn the minute hand clockwise until 10:00 AM is aligned with the triangle on the inner dial. The
hour and the minute dial will show exactly 10:00.
PROGRAMMING
The 24-hour dial has quarter-hour divisions and AM/PM indications. The time switch is programmed by pushing the captive
trippers to the outer ring position for the entire period that the aerator is to be turned "ON," i.e. 15min for each tripper on the 24-
hour dial. When the tripper is pushed to the inside, the switch is in the "OFF" position.
PROGRAMMING WITH MANUAL OVERRIDE SWITCH
Your Timer may have a 3-way manual switch or a 2-way manual switch.
AUTOMATIC MODE In order to operate the time clock in the automatic mode, the manual switch must be in the
automatic postion- see diagram.
MANUAL MODE For the 3-way switch, with the manual override switch in the lower position, marked "O", the time clock
output will remain Permanently OFF. In the upper position, marked "I", the time clock output will remain permanently ON. For the
2-way switch, with the manual override switch in the lower position, marked "ON" the time clock output will remain permanently
ON.
Captive trippers (in
Triangle marker
the on position)
11