Do you have a question about the E25 Series and is the answer not in the manual?
Questions and answers
jack r walker
February 4, 2025
surround removal and glass cleaning
1 comments:
Mr. Anderson
May 14, 2025
To remove the surround on the Enviro E25 Series: 1. Open the safety screen. 2. Lift the safety screen and surround, lining up the hooks with the slots on the side of the cabinet. 3. Unhook the surround from the cabinet.
To clean the glass: 1. Allow the fireplace to cool completely before cleaning. 2. Use a mild glass cleaner and a soft cloth. 3. Do not use abrasive cleaners, as they can damage the glass and painted surfaces. 4. Clean the glass after the first burn, about two weeks later, and then as needed, usually two to three times per season.
Page 1
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Installation and service must be performed by a qualified installer, service agency or the gas supplier. C#4001609 C-15958 Version Française: www.enviro.com/fr.html...
Safety Precautions WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS •...
Page 3
Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed in • A barrier designed to reduce the risk of burns from the accordance with their instructions. Carefully read all the hot veiwing glass is provided with this appliance and shall instructions in this manual first.
After the unit has gone through the first burn, turn the unit off, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner, available at your local ENVIRO dealer. See “D ”...
Specifications ating abeL ocation The rating label is located in the bottom of the unit. imensions 20.8 10.8 27.3 28.8 13.5 24.4 18.5 19.4 14.1 20.7 nstaLL epth The E25 has a minimum install depth of 13.5” (343mm). 990.60 39.00 1.162 652.78 25.70...
Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. e25i L ighting anD uRning nstRuctions FOR YOUR SAFETY READ BEFORE OPERATING...
Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. e25 ( nova ighting anD uRning nstRuctions...
Page 9
After the unit has gone through the first burn, turn the unit OFF, including the pilot, and let the unit get completely cold. Then remove the glass and clean it with a good gas fireplace glass cleaner, available at your local Enviro dealer (See m and m...
Operating Instructions emote ontRoL peRations The Proflame 2 GTMFLSA is a modular remote control system that directs the functions of the E25. The Proflame 2 GTMFLSA is configured to control the on/off main burner operation, its flame levels and provides on/off and Smart thermostatic control of the appliance. The system controls a remotely actuated top light, as well as bottom lights and fan speed each through six (6) levels.
Operating Instructions e25] ot used oN (ifc): ntegRateD iRepLace ontRoLLeR The Proflame 2 IFC connects directly to the gas valve, stepper motor, pilot, covection fan, and accent lights with wiring harnesses. The IFC is mainly powered by 120 VAC but can also run off a battery backup four (4) AA type batteries for shorter periods of time.
Operating Instructions ccessing Due to limited space within the cabinet the IFC & battery pack are located on a sliding tray. Pull the tray forward out of the cabinet to easily access the battery pack and the IFC. The tray has stops to make sure that the cabling is not over stretched.
Operating Instructions peRating RoceDuRe Initializing The System For The First Time Install the four (4) AA batteries into the IFC battery holder. Note the polarity of the battery and insert into the battery bay as indicated on the body of the battery holder. Press and release the reset button The IFC will “beep”...
Page 14
Operating Instructions Remote Flame Control The Proflame 2 GTMF has six (6) flame levels. With the system on, and the flame level at the maximum in the appliance, pressing the Down Arrow Key once will reduce the flame height by one step until the flame is turned off. The Up Arrow Key will increase the flame height each time it is pressed.
Page 15
Operating Instructions Low Battery Power Detection Transmitter: The life span of the remote control batteries depends on various factors: quality of the batteries used, the number of ignitions of the appliance, the number of changes to the room thermostat set point, etc. When the Transmitter batteries are low, a Battery Icon will appear on the LCD display of the Transmitter before all battery power is lost.
Operating Instructions entuRi Djustment The venturi adjustment slider is located in the centre of the unit, below the door (see Figure 4). The venturi allows the amount of air coming into the fireplace to be adjusted in order to accommodate different climates and venting arrangements.
Maintenance And Service Warning: Failure to position the parts in accordance with this manual, or failure to use only parts specifically approved with this appliance, may result in property damage or personal injury. At least once a year, run through the following procedures to ensure the system is clean and working properly.
The glass must be purchased from an ENVIRO dealer. No substitute materials are allowed. Remove the door (see page 16). The replacement glass will come with a new gasket installed. Remove any silicone remnants from the door.
Maintenance And Service uRneR emovaL The burner may need to be removed for a few reasons, including cleaning under the burner, converting the unit to a different gas type, or to replace the burner altogether. Proceed only when the unit has completely cooled down. Open door and remove Remove log stands and log grate.
E25i & E25 Gas fuel Conversion Instructions Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
Page 21
NOVA SPECIFIC INSTRUCTIONS To gain access to the valve you will need to remove The valve is located in the rear left corner of the front control panel. Remove the the unit. You will need to remove the rod and cap Qty-3 T20 screws holding the control panel on.
Page 22
IPI SPECIFIC INSTRUCTIONS Pilot Adjustment Inlet Screw Pressure Tap Stepper Regulator Manifold Pressure Tap 7. Convert the SIT gas valve: Disconnect the wire harness from the IFC. Use a T-20 driver to remove the two screws that hold the servo regulator to the gas valve.
Initial Installation Surround Assembly The surround needs to be assembled be on site. you will need a 7/16” socket or wrench. Lay down protective material where you intend to assemble surround. Carefully unwrap all parts making sure not to scratch the paint. Line up surrounds parts aligning the corners Place the Sandwich plate over the studs.
Initial Installation QUALIFIED INSTALLERS ONLY WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. LeaRances to ombustibLes Maintain sufficient clearances for operation, service Minimum Mantle Clearances and maintenance.
Page 25
Refractory, glass door, safety screen, and log set can be removed from the fireplace prior to installation. The ENVIRO E25 may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National, Provincial/State and local building codes and has been constructed of non-combustible materials.
Initial Installation QUALIFIED INSTALLERS ONLY xhaust estRictoR This fireplace has an internal exhaust restrictor rings. Usage of the restrictor rings is dependant on the length of venting required and different installation requirements. Use the restrictor rings at your discretion. Be sure a clean healthy burn is 2.5”...
Page 27
Initial Installation QUALIFIED INSTALLERS ONLY Minimum Clearance* Description Clearance above the highest point where it passes through a roof surface, refer to 3 ft (0.9 m) Figure 23. Clearance above a roof ridge, any other portion of a building, or any other obstruc- 24 in (0.6 m) tion within a horizontal distance of 10 feet (3 m), refer to Figure 23.
Page 28
Initial Installation QUALIFIED INSTALLERS ONLY 10. If the fireplace opening is lower than 24” (610 mm), remove the vent collar plate from the top of the insert by unlatching the hook located on the center top of the stove above the door opening (see Figure 29).
Initial Installation QUALIFIED INSTALLERS ONLY Horizontal Termination kits The E25 is certified for use with: Duravant - 46DBA-HCL33 ICC - TM-ALH (50-3664) The minimum height that either horizontal kit can be installed at is 6ft. Horizontal termination Vent Height is Measured from the top of the fireplace cabinet.
Initial Installation QUALIFIED INSTALLERS ONLY (zc) f LeaRance iRepLace nstaLLation The metal floor of the ZC solid fuel firebox can be removed to allow the installation of the insert. THE CLEARANCE TO COMBUSTIBLE MATERIAL UNDER THE INSERT IS 0” (0 mm). YOU DO NOT NEED TO RAISE THE UNIT OFF OF A COMBUSTIBLE FLOOR.
Initial Installation QUALIFIED INSTALLERS ONLY Proflame 2 System - Wiring Diagram Transmitter - TMFLSA IPI Pilot 885 Gas Valve Battery Holder Main On/Off Main Harness Convection Fan Power Cord...
Initial Installation QUALIFIED INSTALLERS ONLY onnection WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. Gas Line Connection: • Prior to installation consult your local authorities codes or the CAN/CGA B 149 (1 or 2) installation code in Canada, or in the USA gas installations follow either local codes or the current edition of the National Fuel Gas Code ANSI Z223.1.
Initial Installation Log Setup Guide Place back log at back of Rotate the log grate (A) into firebox, over top of pilot hood. slots on log deflector (B). Locate notches on log stand (A) Locate notches on log stand (A) into holes on log deflector.
Page 35
Place log on log stand. The back left corner of Place log on log stand. The back right corner of the log locates into the corner of the log stand the log locates into the corner of the log stand Insert the (A) log onto the back pin aligning the Using the brush supplied, lightly brush the ember wool front of the log to the flat part of the front log.
A small amount on the bottom side of the logs is normal. Remove and replace the logs in the same manner described above. If new logs are required, contact your nearest ENVIRO dealer. Never operate the fireplace with the glass door removed.
TroubleShooting iagnostic Lash oDes 1. Fail to ignite: If there is no positive ignition, the board will go into lock out and the LED will blink 3 times in intervals until the system is reset. 2. Low battery condition (<4V): the LED indicator will blink one (1) time in intervals. 3.
Page 38
TroubleShooting Problem Possible Cause Solution The pilot flame has gone out Thermostat · Turn it ON does not The On/Off switch is turn to OFF work The thermostat is set too high · Set the thermostat to a lower temperature ·...
Page 39
TroubleShooting Problem Possible Cause Solution · Turn the system off by pressing the ON/OFF button on the transmitter · After approximately 2 seconds press the ON/OFF button on the transmitter again. · In the manual flame control mode, use the down arrow button to reduce the flame to off, indicated by the word OFF displayed on the transmitter LCD screen.
Parts List Reference Part Description Part Number Number E25 Log Grate 50-3989 Door Release Tool 50-2510 Flue Adapter Tool 50-3505 E25 Exhaust Restrictors 50-3990 Proflame 2 Transmitter (0.584.045) 50-3028 Fan Controller EG28-045 FPI Burner Switch EC-026 Battery Holder 4 x AA 50-3027 E25 Power Cord (115V) EC-042...
Sherwood Industries Ltd. (“Sherwood”) hereby warrants, subject to the terms and conditions herein set forth, this product against defects in material and workmanship An expanded list of exclusions is available at www.enviro.com/help/warranty.html during the specified warranty period starting from the date of original purchase at retail.
Need help?
Do you have a question about the E25 Series and is the answer not in the manual?
Questions and answers
surround removal and glass cleaning
To remove the surround on the Enviro E25 Series:
1. Open the safety screen.
2. Lift the safety screen and surround, lining up the hooks with the slots on the side of the cabinet.
3. Unhook the surround from the cabinet.
To clean the glass:
1. Allow the fireplace to cool completely before cleaning.
2. Use a mild glass cleaner and a soft cloth.
3. Do not use abrasive cleaners, as they can damage the glass and painted surfaces.
4. Clean the glass after the first burn, about two weeks later, and then as needed, usually two to three times per season.
This answer is automatically generated