Enviro EX32 Owner's Manual
Enviro EX32 Owner's Manual

Enviro EX32 Owner's Manual

Ipi gas fireplace insert
Hide thumbs Also See for EX32:

Advertisement

EX32
I P I G A S F I R E P L A C E I N S E R T
OWNER'S MANUAL
WARNING:
If the information in this manual is not followed exactly, a
fire or explosion may result causing property damage, personal injury
or loss of life. Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
4001609
1
50-3520
Version Française: www.enviro.com/fr.html

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EX32 and is the answer not in the manual?

Questions and answers

Summary of Contents for Enviro EX32

  • Page 1 If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Installation and service must be performed by a qualified installer, service agency or the gas supplier. 4001609 50-3520 Version Française: www.enviro.com/fr.html...
  • Page 2: Safety Precautions

    Safety Precautions WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS •...
  • Page 3 NEVER ALLOW CHILDREN shut. TO TOUCH GLASS. • If the EX32 unit is pulled out of its installation, and the A barrier designed to reduce the risk of burns from the vent-air intake system is disconnected for any reason, hot viewing glass is provided with this appliance and shall...
  • Page 4: Table Of Contents

    Table of Contents Safety Precautions......................2 Table of Contents......................4 Codes And Approvals.......................5 Specifications........................6 Rating Label Location...................6 Dimensions......................6 Install Depths.......................6 EX32 Options Dimensions..................7 Operating Instructions.....................8 Lighting and Turning Off Instructions..............8 Venturi Adjustment....................9 Normal Sounds During Operation.................9 Remote Control Operations...................9 System Description.....................10 Technical Data....................10 Transmitter....................10...
  • Page 5: Codes And Approvals

    After the unit has gone through the first burn, turn the unit off, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner, available at your local ENVIRO dealer. See “D ”...
  • Page 6: Specifications

    8 " [447] Figure 1: EX32 Exterior Dimensions. nstaLL epth The EX32 has a minimum install depth of 16” (406mm). The table below shows what depth of install is required with each surround panel. Surrround Panel Required Install Depth Contemporary 16”...
  • Page 7: Ex32 Options Dimensions

    Specifications 8 " 25" 8 " 8 " Figure 2: EX32 Contemporary Surround with Base Shelf and Riser. Table 2: EX32 Options Dimensions. Contemporary Surround Extruded Surround Height 25” (635mm) 25” (635mm) Width ” (1013 mm) ” (1013 mm) Trimmable...
  • Page 8: Operating Instructions

    Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ighting anD uRning nstRuctions FOR YOUR SAFETY READ BEFORE OPERATING WARNING:...
  • Page 9: Venturi Adjustment

    The Proflame 2 GTMFLSA is a modular remote control system that directs the functions of the EX32. The Proflame 2 GTMFLSA is configured to control the on/off main burner operation, its flame levels and provides on/off and Smart thermostatic control of the appliance. The system controls a remotely actuated...
  • Page 10: System Description

    Operating Instructions ystem escRiption The Proflame 2 Remote Control System consists of two (2) elements: 1. Proflame 2 Transmitter. 2. Integrated Fireplace Controller (IFC) and wiring harness to connect to the gas valve, stepper motor battery holder, convection fan, and lights. ATTENTION! - TURN “OFF”...
  • Page 11: Integrated Fireplace Controller (Ifc)

    Key Lock Transmission Low battery alarm Thermostat OFF/ Room ON/SMART Temperature CPI mode Set Point Aux ON Temperature/Level/State eX32] ot used oN Flame ON Split Flow Dimmer ON Comfort fan Figure 6: Proflame 2 Transmitter LCD Screen. (ifc): ntegRateD iRepLace ontRoLLeR The Proflame 2 IFC (Figure 7) connects directly to the gas valve, stepper motor, pilot, covection fan, and accent lights with wiring harnesses.
  • Page 12: Operating Procedure

    Operating Instructions peRating RoceDuRe Initializing The System For The First Time Install the four (4) AA batteries into the IFC battery holder. Note the polarity of the battery and insert into the battery bay as indicated on the body of the battery holder. Press and release the reset button (see Figure 7). The IFC will “beep”...
  • Page 13 Flame Off Figure 11: Remote Control’s Flame Levels. Fan Control The EX32 comes with a convection fan that can be controlled with the Transmitter. The fan speed can be adjusted thorugh six (6) speeds. To control the fan press the MODE key (Figure 5) to index to the fan...
  • Page 14 Operating Instructions Split Flow Control This function is not used on the EX32 and can be disregarded. Figure 14: Split Flow Control Top Light Control For added ambiance the EX32 also has a light at the top of the fireplace that can be controlled with the Transmitter.
  • Page 15 Operating Instructions Low Battery Power Detection Transmitter: The life span of the remote control batteries depends on various factors: quality of the batteries used, the number of ignitions of the appliance, the number of changes to the room thermostat set point, etc. When the Transmitter batteries are low, a Battery Icon will appear on the LCD display of the Transmitter (see Figure 17) before all battery power is lost.
  • Page 16: Maintenance And Service

    Maintenance And Service Warning: Failure to position the parts in accordance with this manual, or failure to use only parts specifically approved with this appliance, may result in property damage or personal injury. At least once a year, run through the following procedures to ensure the system is clean and working properly.
  • Page 17: Cleaning The Glass

    The glass must be purchased from an ENVIRO dealer. No substitute materials are allowed. Remove the door (see page 16). The replacement glass will come with a new gasket installed. Remove any silicone remnants from the door.
  • Page 18: Burner Removal

    Maintenance And Service uRneR emoVaL The burner may need to be removed for a few reasons, including cleaning under the burner, converting the unit to a different gas type, or to replace the burner altogether. Proceed only when the unit has completely cooled down. 1.
  • Page 19: Ember Lights - Bulb Replacement

    Maintenance And Service mbeR ights epLacement The front ember light assembly consists of 5 halogen bulbs. Over time, should one of these bulbs require replacement follow the steps below for the proper procedure. Proceed only when then fireplace has been turned off and has completely cooled down. Note: Gloves should be worn to avoid skin contact with halogen bulb.
  • Page 20: Fuel Conversion

    The installation is not proper or complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit. Kit Parts List for all EX32 models: 1 - Orifice (NG: #37) or (LP: #52) 1 - Servo Regulator with diaphragm...
  • Page 21 If the EX32 has been installed at an altitude higher than 2000ft (610m) it is required to estIng de-rate the unit accordingly: In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 2000 (610 m) feet is to be reduced 4% for each 1000 feet (305 m) above sea level.
  • Page 22: Initial Installation

    The vent length for the EX32 must be between 10ft (3.05 m) and 40ft (12.2 m). The EX32 intake and exhaust must be connected to 3” dia. flexible venting, made of either aluminum or stainless steel, leading into a vertical termination cap. The flue collars of this model will fit inside of a standard 3”...
  • Page 23 Check for any tears in the liner at this point. IMPORTANT: The screws that hold the vent collar plate in its approved position must be installed. NOTE: If the EX32 unit is pulled out of its installation, and the vent air intake system is disconnected for any reason, ensure that the vent-air intake pipes are re-sealed with high-temperature sealant and...
  • Page 24: Clearances To Combustibles

    1. Plan your installation and clearances to combustibles. The EX32 may be installed and vented into any solid 2ft (0.6m)
  • Page 25 *Clearances are in accordance with local installation codes and the requiremenets of the gas supplier 4. Check that the chimney clean outs fit properly. The flue damper must be fully blocked open or removed for installation of the EX32; the smoke shelves, shields and baffles may be removed if attached by mechanical fasteners.
  • Page 26 Initial Installation QUALIFIED INSTALLERS ONLY 10. If the fireplace opening is lower than 24” (610 mm), remove the vent collar plate from the top of the insert by unlatching the hook located on the center top of the stove above the door opening (see Figure 29).
  • Page 27: Zero Clearance Fireplace Installation

    Initial Installation QUALIFIED INSTALLERS ONLY (zc) f LeaRance iRepLace nstaLLation The metal floor of the ZC solid fuel firebox can be removed to allow the installation of the insert. THE CLEARANCE TO COMBUSTIBLE MATERIAL UNDER THE INSERT IS 1/2” (13 mm). YOU MUST RAISE THE INSERT A MINIMUM OF 1/2”...
  • Page 28 Initial Installation QUALIFIED INSTALLERS ONLY Proflame 2 System - Wiring Diagram Transmitter - TMFLSA IPI Pilot 885 Gas Valve Battery Holder Main On/Off Main Harness Light Convection Fan Ember Lights Power Cord Figure 33: Wiring Schematic.
  • Page 29: Gas Line Connection

    Initial Installation QUALIFIED INSTALLERS ONLY onnection WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. Gas Line Connection: • Prior to installation consult your local authorities codes or the CAN/CGA B 149 (1 or 2) installation code in Canada, or in the USA gas installations follow either local codes or the current edition of the National Fuel Gas Code ANSI Z223.1.
  • Page 30: Adjusting The Pilot Flame

    Initial Installation QUALIFIED INSTALLERS ONLY Table 9: Orifice and Pressure Information. EX32 With Log Set & Proflame Valve Main Burner Natural Gas Propane Gas Orifice: #37 DMS #52 DMS Max. Manifold Press: 3.6 W.C. (0.89 KPa) 10.0” W.C. (2.49 KPa) Min.
  • Page 31: Secondary Installation

    Secondary Installation & R ptionaL heLf iseR The optional Base Shelf (1⅝” (41 mm) high) and Base Shelf Riser (2⅛” (54 mm) high) are components that can be combined to create a riser with an overall height of 2 ” (55 mm). This shelf can be installed with or without the riser and can be used when the hearth in front of the unit is lower than the fireplace opening.
  • Page 32: Surround Panel Installation

    Secondary Installation uRRounD aneL nstaLLation WARNING: The surround becomes hot when the unit is operating; ensure that the unit is turned off, and that it has cooled to room temperature before beginning this installation. Height Width 3-Sided Surround 25” (635 mm) ”...
  • Page 33: Optional 3 And 4 Sided Trimmable Panels

    Secondary Installation ptionaL iDeD RimmabLe aneLs Modifying the Surround Panel: Trimmable Surround Panels are large rectangular panels that may be cut for use in cases that a non-standard fireplace opening (e.g. an arched opening) is to be filled. Optionally this surround can be left uncut and placed in front of the fireplace opening.
  • Page 34: Log Set Installation

    Secondary Installation nstaLLation The placement of the logs is not arbitrary. If they are positioned incorrectly, the flames can be “pinched” and will not burn correctly. All of the logs come with either a drilled hole or notch to make alignment easier.
  • Page 35 Secondary Installation 5. Install the final ember log, as shown in Figure 48, by locating the drilled holes on the burner pins. Then install the first right top log by sitting the depression on the bottom side onto the half-round on top of the back log. The opposite end of the log sits into the notch on top of the right ember log.
  • Page 36 A small amount on the bottom side of the logs is normal. Remove and replace the logs in the same manner described above. If new logs are required, contact your nearest ENVIRO dealer. Never operate the fireplace with the glass door removed.
  • Page 37: Troubleshooting

    TroubleShooting iagnostic Lash oDes 1. Fail to ignite: If there is no positive ignition, the board will go into lock out and the LED will blink 3 times in intervals until the system is reset. 2. Low battery condition (<4V): the LED indicator will blink one (1) time in intervals. 3.
  • Page 38: Troubleshooting

    TroubleShooting Problem Possible Cause Solution The pilot flame has gone out Thermostat · Turn it ON does not The On/Off switch is turn to OFF work The thermostat is set too high · Set the thermostat to a lower temperature ·...
  • Page 39 TroubleShooting Problem Possible Cause Solution · Turn the system off by pressing the ON/OFF button on the transmitter · After approximately 2 seconds press the ON/OFF button on the transmitter again. · In the manual flame control mode, use the down arrow button to reduce the flame to off, indicated by the word OFF displayed on the transmitter LCD screen.
  • Page 40: Parts List

    Proflame 2 Transmitter (0.584.040) 50-3265 Power Cord (115V) EC-042 Strain Relief EC-044 EX32 Conversion Kit NG to LP 50-3503 EX32 Conversion Kit LP to NG 50-3546 Ceramic Wool Embers Only 50-893 12 oz. Can of Metallic Black Touch Up Paint...
  • Page 41: Parts Diagram - Components

    Parts Diagram - Components...
  • Page 42: Notes

    Notes...
  • Page 43: Warranty

    Exclusions conditions herein set forth, this product against defects in material and workmanship An expanded list of exclusions is available at www.enviro.com/help/warranty.html during the specified warranty period starting from the date of original purchase at retail. This warranty does not cover: In the event of a defect of material or workmanship during the specified warranty period, ...
  • Page 44: Installation Data Sheet

    � NATURAL GAS (NAT) PROPANE(LPG) _________________________________________ INLET GAS PRESSURE:_________in WC PHONE:___________________________________ MAIN BURNER ORIFICE:__________# DMS PILOT ORIFICE #_________OR________in diam. INSTALLER’S SIGNATURE: _________________________________________ MANUFACTURED BY: SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD RD. SAANICHTON, BC, CANADA V8M 2A3 www.enviro.com May 22, 2018 C-15090...