FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapours and liquids in the vicinity of this or any
other appliance.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified
WARNING:
If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, personal
injury or loss of life. Installation and service
must be performed by a qualified installer,
service agency or the gas supplier.
O- T L
Tested &
Portland
Listed By
Oregon USA
C
US
OMNI-Test Laboratories, Inc,
Report # 268-S-23-5
Report # 268-S-06b-2
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
Version Française: www.enviro.com/fr.html
E30
Log Set & Nova Valve
OWNER'S MANUAL
kit is used.
Massachusetts installations (Warning): This product must be installed by a licensed
plumber or gas fitter when installed within the Commonwealth of Massachusetts. Other
Massachusetts code requirements: Flexible connector must not be longer than 36in.,
a shut off valve must be installed; only direct vent sealed combustion products are
approved for bedrooms/bathrooms. A carbon monoxide detector is required in all rooms
containing gas fired direct vent appliances. The fireplace damper must be removed or
welded in the open position prior to installation of a fireplace insert.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Gas Insert -
Leave this manual with the appliance.
Retain this manual for future reference.
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open
flame.
• Do not try to light any appliance.
• Do not touch any electrical switch
or use any phone in your building.
• Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
• If you cannot reach your gas
supplier, call the fire department.
INSTALLER:
CONSUMER:
50-2498

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E30 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Enviro E30

  • Page 1 Report # 268-S-06b-2 welded in the open position prior to installation of a fireplace insert. SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE 50-2498 Version Française: www.enviro.com/fr.html...
  • Page 2: Safety Precautions

    Do not abuse the glass by striking it or slamming the door shut. HOT GLASS WILL • If the E30 unit is pulled out of its installation, and CAUSE BURNS the vent-air intake system is disconnected for any reason, ensure that the vent-air intake pipes are reconnected and...
  • Page 3: Table Of Contents

    Removing Valve Cover..................12 Fuel Conversion....................12 Initial Installation......................15 Clearances to Combustibles.................15 Minimum Fireplace Size..................15 Direct Vent Model....................15 Preparing Your E30 For Installation................16 Venting Fireplace Inserts..................17 Zero Clearance Fireplace Installation..............18 Direct Vent Vertical Vent Termination..............19 Electrical Requirements..................21 Gas Line Connection...................22 Adjusting The Pilot Flame..................24 Secondary Installation....................25...
  • Page 4: Codes And Approvals

    After the unit has gone through the first burn, turn the unit off, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner, available at your local ENVIRO dealer. See “D ”...
  • Page 5: Specifications

    The rating label is located on the bottom of the unit, behind the front access door. imensions 17.89 6.94 6.94 13.73 12.05 27.56 2.06 26.56 24.38 FRONT 14.06 16.25 19.88 19.61 18.65 16.49 2.38 3.07 LEFT RIGHT 1.30 15.81 Figure 1: E30 Exterior Dimensions.
  • Page 6: E30 Options Dimensions

    Specifications 8 " 25" 8 " 8 " Figure 2: E30 Contemporary Surround with Base Shelf and Riser. Table 1: E30 Options Dimensions. Regular Surround Contemporary Surround Extruded Surround Height 25” (635mm) 25” (635mm) 25” (635mm) Width ” (1013 mm) ”...
  • Page 7: Operating Instructions

    Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ighting anD uRning nstRuctions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING...
  • Page 8: Pilot Light

    Operating Instructions iLot ight 1. Turn off the gas to the fireplace. If not recently done, remove the glass and let the unit air out for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints with Thermocouple Thermopile soapy water.
  • Page 9: Burner Lighting

    After the unit has gone through the first burn, turn the unit OFF, including the pilot, and let the unit completely cool. Then remove the door and clean the glass with a good gas fireplace glass cleaner, available at your local Enviro dealer. See m aIntenance...
  • Page 10: Maintenance And Service

    The glass must be purchased from an ENVIRO dealer. No substitute materials are allowed. Remove the door (see page 11). The replacement glass will come with a new gasket installed. Remove any silicone remnants from the door.
  • Page 11: Glass Door Removal

    Maintenance And Service Lass emoVaL Figure 8: Door Release. Figure 9: Door Removal. Remove the glass door by placing the hooked end of the door release tool in the hole on the door latch mechanism (see Figure 8) and pulling the latch out then over to the center of the unit.
  • Page 12: Removing Valve Cover

    Maintenance And Service emoVing aLVe oVeR The valve cover can be removed to access the gas valve. 1. Remove the glass door as shown in m aIntenance anD erVIce lass emoVal 2. Remove the log set and ember material. Refer to s econDary nstallatIon et anD...
  • Page 13: Fuel Conversion

    Fuel Conversion TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before installing. WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction.
  • Page 14 Fuel Conversion d) Insert a ” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure 12), rotate it counter-clockwise until it is free and extract it. e) Flip the screw (refer to Figure 13). f) Using the Allen wrench as shown in Figure 12, rotate the screw clockwise. WARNING! Do not over tighten the screw.
  • Page 15: Initial Installation

    The vent length for the E30 must be between 8ft (2.44 m) and 30ft (9.14 m). This model is vented with a 3” intake and a 3” exhaust aluminum or stainless steel flex vent leading into a vertical termination cap.
  • Page 16: Preparing Your E30 For Installation

    Check for any tears in the liner at this point. IMPORTANT: The screws that hold the vent collar plate in its approved position must be installed. NOTE: If the E30 unit is pulled out of its installation, and the vent air intake system is disconnected for any reason, ensure that the vent-air intake pipes are re-sealed with high-temperature sealant and reconnected with three (3) sheet metal screws evenly spaced.
  • Page 17: Venting Fireplace Inserts

    Refractory, glass doors, screen rails, screen mesh and log grates can be removed from the fireplace before installing the unit. Figure 18: Installation of E30 DV . The height for the vent must be between 8 ft (2.44 m) and 30 ft (9.14 m).
  • Page 18: Zero Clearance Fireplace Installation

    1. Plan your installation and clearances to combustibles. The E30 may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National, Provincial/State and local building codes and has been constructed of non-combustible materials. Also refer to the I...
  • Page 19: Direct Vent Vertical Vent Termination

    4. Check that the chimney clean outs fit properly. The flue damper must be fully blocked open or removed for installation of the E30; the smoke shelves, shields and baffles may be removed if attached by mechanical fasteners.
  • Page 20 Initial Installation QUALIFIED INSTALLERS ONLY (zc) f LeaRance iRePLace nstaLLation The metal floor of the ZC solid fuel firebox can be removed to allow the installation of the insert. THE CLEARANCE TO COMBUSTIBLE MATERIAL UNDER THE INSERT IS 2 ” (57.2 mm). YOU MUST USE THE LEVELING LEGS TO RAISE THE INSERT A MINIMUM OF 2 ”...
  • Page 21: Electrical Requirements

    Initial Installation QUALIFIED INSTALLERS ONLY LectRicaL equiRements The fan will not operate if the appliance is cold. Once the unit is lit and the fan is set to the desired level, the fan will automatically turn on upon reaching operating temperature. The fan will automatically turn off after the appliance has cooled down.
  • Page 22: Gas Line Connection

    ½ psig (3.45 KPa) or the valve will be damaged. Figure 26: ⅜” NPT Male Pipe Nipple with Cover Removed. Table 5: Orifice and Pressure Information. E30 With Log Set & Nova Valve Main Burner Natural Gas Propane Gas Orifice:...
  • Page 23 Initial Installation QUALIFIED INSTALLERS ONLY TO TEST VALVE PRESSURES (INPUT RATES): The pressure taps are located on the front side of the valve (see Figure 27). 1. Remove valve control knobs, then remove control panel. 2. Using a long flat bladed screwdriver, turn set screw one (1) turn counter-clockwise to loosen. 3.
  • Page 24: Adjusting The Pilot Flame

    Initial Installation QUALIFIED INSTALLERS ONLY Djusting iLot Lame The pilot flow adjustment is set to maximum at the factory and should not need to be adjusted. The pilot flame should envelope ⅜” to ½” (10 to 13mm) of the thermocouple (see Figure 28). However, should the need arise, follow Steps 1- 2 below.
  • Page 25: Secondary Installation

    Additional Base Shelf Risers can be fastened together to increase the height in increments of 2⅛” (54 mm). This Base Shelf may be used in conjunction with the any of the E30 surround panel options, and it may also be used with the E30 Trimmable Surround. The Base Shelf and Riser are sold separately.
  • Page 26: Optional 3 And 4 Sided Trim-Able Panels

    Modifying the Surround Panel: The E30 Trimmable Surround Panels are large rectangular panels that may be cut for use in cases that a non- standard fireplace opening (e.g. an arched opening) is to be filled. Optionally this surround can be left uncut and placed in front of the fireplace opening.
  • Page 27: Surround Panel Installation

    The wiring harness for the burner switch has one (1) blue wire, one (1) grey wire and two (2) purple wires. The blue wire connects to the blue wire on the E30 unit, the grey wire connects to the grey wire on the E30 unit, and the purple wires are used to connect an optional thermostat.
  • Page 28: Firebox Liner And Burner Tube Removal / Installation

    NOTE: The firebox liners are fragile and should be handled gently. 1. Ensure the E30 is turned off and allow the unit to cool. 2. Remove the glass door as shown in the m aIntenance anD erVIce...
  • Page 29: Log Set And Ember Removal / Installation

    Secondary Installation et anD mbeR nstaLLation NOTE: The logs are fragile and should be handled gently. WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury (see Figures 43 through 47).
  • Page 30 Secondary Installation et anD mbeR nstaLLation PLACEMENT OF EMBER BED Figure 45: Place the ember bed in the center of the burner tube and pull it forward as far as it will go. Ensure it DOES NOT obstruct any part of the burner. Left Side of Ember Bed Sitting inside burner tube The Ember Bed should sit flat on the support brackets as shown above.
  • Page 31 Secondary Installation Figure 46: Place the log grate in front of the burner tube using the two slotted mounts underneath. Figure 46. Third Stage Log Set Installation. Figure 47: The ember wool comes in chunks that can be ripped into smaller pieces.
  • Page 32 Secondary Installation Figure 49: Place the small left and right logs as shown. The bottoms of both pieces have contours to fit on the log grate. Figure 49. Sixth Stage Log Set Installation. Figure 50: Place the two center logs as shown.
  • Page 33: Trouble Shooting

    Trouble Shooting Problem Possible Cause Solution The main burner The gas valve may not be on. • Check that the gas control knob is in the “ON” position. does not ignite Thermostat is not calling for • Adjust the thermostat several degrees above ambient temperature. when called for.
  • Page 34: Parts List

    E30 Control Panel Knobs (Set 2) 50-2355 Burner Tube 50-2504 E30 Door Complete 50-2505 E30 Glass C/W Gasket (21.75” X 13.575”) 50-2506 Dual Bulb Door Gasket (10ft) 50-634 E30 Valve Cover with Gasket 50-2503 E30 Valve Extension C/W Knob (Short)
  • Page 35 Parts List Reference Part Description Part Number Number E30 Door Latch Mechanism (Set of 2) 50-2507 E30 Logset (9 pcs) 50-2508 Brick Liner - E30 50-2509 S.I.T. Nova Valve Convertible 50-1421 120 Ceramic Fan Temp Sensor EC-001 12 oz. Can of Metallic Black Touch Up Paint...
  • Page 36: Parts Diagram - Components

    Parts Diagram - Components...
  • Page 37 Parts Diagram - Options...
  • Page 38: Warranty

    Exclusions conditions herein set forth, this product against defects in material and workmanship An expanded list of exclusions is available at www.enviro.com/help/warranty.html during the specified warranty period starting from the date of original purchase at retail. This warranty does not cover: In the event of a defect of material or workmanship during the specified warranty period, ƒ...
  • Page 39 � NATURAL GAS (NAT) PROPANE(LPG) _________________________________________ INLET GAS PRESSURE:_________in WC PHONE:___________________________________ MAIN BURNER ORIFICE:__________# DMS PILOT ORIFICE #_________OR________in diam. INSTALLER’S SIGNATURE: _________________________________________ MANUFACTURED BY: SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD RD. SAANICHTON, BC, CANADA V8M 2A3 www.enviro.com March 18, 2013 C-13828...

Table of Contents

Save PDF