Enviro E20I Owner's Manual
Hide thumbs Also See for E20I:

Advertisement

Quick Links

E20I
G A S F I R E P L A C E I N S E R T
OWNER'S MANUAL
WARNING:
If the information in this manual is not followed exactly, a
fire or explosion may result causing property damage, personal injury
or loss of life. Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
4001609
50-2261
Version Française: www.enviro.com/fr.html
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E20I and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Enviro E20I

  • Page 1 If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Installation and service must be performed by a qualified installer, service agency or the gas supplier. 4001609 50-2261 Version Française: www.enviro.com/fr.html...
  • Page 2: Safety Precautions

    Safety Precautions WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS •...
  • Page 3 FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fi red appliances must be installed in • A barrier designed to reduce the risk of burns from the accordance with their instructions. Carefully read all the hot veiwing glass is provided with this appliance and shall instructions in this manual fi rst.
  • Page 4: Table Of Contents

    Table of Contents Safety Precautions..........................2 Table of Contents..........................4 Codes And Approvals..........................5 Specifications........................6 Rating Label Location.......................6 Dimensions......................6 Install Depth..........................6 E20 Options Dimensions......................7 Operating Instructions..........................8 Lighting and Turning Off Instructions..................8 Venturi Adjustment........................9 Normal Sounds During Operation....................9 Tra n s m i tt e r..................1 0 Initializing the System for the First Time..................12 Switching to Continuous Pilot....................12 Turn off the Appliance......................13...
  • Page 5: Codes And Approvals

    After the unit has gone through the first burn, turn the unit off, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner, available at your local ENVIRO dealer. See “D ”...
  • Page 6: Specifications

    Specifications ating abeL ocation The rating label is located on the left side of the unit and is attached to a rectangular metal sheet that is chained to the fireplace. imensions 17.726 14.000 8.847 *Shown with 2.226 Contemporary surround panel and Extensions* 13.284 11.737...
  • Page 7: E20 Options Dimensions

    Specifications ” (898mm) ” (594mm) ” 26” (648mm) (660mm) ” (975mm) Figure 2: E20 Contemporary Surround with Base Shelf and Riser. Table 1: E20 Options Dimensions. Regular Surround Contemporary Surround Extruded Surround Height ” (594mm) ” (594mm) ” (594mm) Width ”...
  • Page 8: Operating Instructions

    Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ighting anD uRning nstRuctions FOR YOUR SAFETY READ BEFORE OPERATING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION...
  • Page 9: Venturi Adjustment

    After the unit has gone through the first burn, turn the unit OFF, including the pilot, and let the unit completely cool. Then remove the glass and clean it with a good gas fireplace glass cleaner, available at your local Enviro dealer. See m ainTenanCe...
  • Page 10: Tra N S M I Tt E

    Operating Instructions emote ontRoL peRations Proflame 2 is a modular remote control system that directs the functions of the E20. The Proflame 2 TMFSLA is configured to control the on/off main burner operation, its flame levels and provides on/off and Smart thermostatic control of the appliance. The system also controls the fan speed through six (6) levels.
  • Page 11 Operating Instructions Key Lock Transmission Low battery alarm Thermostat OFF/ Room ON/SMART Temperature CPI mode Set Point Aux ON Temperature/Level/State Flame ON Split Flow Dimmer ON Comfort fan Figure 6: Proflame 2 Transmitter LCD Screen. (ifc): ntegRateD iRepLace ontRoLLeR The Proflame 2 IFC (Figure 7) connects directly to the gas valve, split flow valve, stepper motor, pilot and covection fan with a wiring harness.
  • Page 12: Initializing The System For The First Time

    When the E20I is turned off press the mode key to index to the constant pilot (CPI) mode icon (see figure 9). Pressing the up arrow key will select Continuous Pilot Ignition (CPI) and pressing the down arrow key will return to IPI.
  • Page 13: Turn Off The Appliance

    Figure 12: Remote Control’s Flame Levels. Fan Control The E20I has a convection fan that can be controlled with the Transmitter. The fan speed can be adjusted thorugh six (6) speeds. To control the fan press the Mode key to index to the fan control icon.
  • Page 14: Key Lock

    Operating Instructions Auxiliary Control This function is not used on the E20I and can be disregarded. Figure 14: Auxiliary Control (not used) Dimmer Control This function is not used on the E20I and can be disregarded. Figure 15: Dimmer Control Key lock This function will lock the keys to avoid unsupervised operation.
  • Page 15: Maintenance And Service

    Do not operate with the glass front removed, cracked or broken. Removal and replacement of the glass from the door must be done by a licensed or qualified service person. The glass must be purchased from an ENVIRO dealer. No substitute materials are allowed.
  • Page 16: Glass Door Removal

    Maintenance And Service Lass emoVaL Figure 19: Door Release. Figure 20: Door Removal. Remove the glass door by placing the hooked end of the door release tool in the hole on the door latch mechanism (see Figure 19) and pulling the latch out then up over the lip on the door.
  • Page 17: Removing Valve Cover

    Maintenance And Service emoVing aLVe oVeR The valve cover can be removed to access the gas valve, the fan, wiring harness, or other components. 1. Remove the glass door as shown in the ainTenanCe anD erviCe lass emoval 2. Carefully remove the log set, ember material, and brick panels, refer to eConDary nsTallaTion...
  • Page 18: Conversion Kit Instalation

    Maintenance And Service Kit Parts List: 1 - Orifice (Natural Gas #44 DMS or Propane #55 DMS) 1 - Stepper Motor (Natural Gas or Propane) 1 - Conversion label 1 - Installation instruction sheet Carefully inspect the orifice supplied with this conversion kit. If it has been damaged or is missing, contact your dealer, distributor or courier company to have them replaced before starting this installation.
  • Page 19 Maintenance And Service Maintenance And Service 7. Convert the SIT gas valve: a) Use a T-20 driver to remove the two screws that hold the servo regulator to the gas valve and disconnect the wire harness from the IFC. b) Remove the rubber regulator diaphragm that is situated between the servo regulator and the valve body.
  • Page 20: Initial Installation

    Initial Installation WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. LeaRances to ombustibLes Maintain sufficient clearances for operation, service and maintenance. • A clearance of 7½” (191 mm) minimum is required from the side of the unit to the sidewalls. •...
  • Page 21: Preparing Your E20 For Installation

    Initial Installation QUALIFIED INSTALLERS ONLY e20 f RepaRing nstaLLation • Remove the packaging from the appliance and surround panels; check to make sure there is no damage. Carefully check the glass door. Do not use the unit if it is damaged. In the event damage is found, please report it to both the courier and your dealer as soon as possible.
  • Page 22: Venting Fireplace Inserts

    The Enviro E20 may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National, Provincial/State and local building codes and has been constructed of non- combustible materials. Before starting, refer to i...
  • Page 23: Direct Vent Vertical Vent Termination

    Initial Installation QUALIFIED INSTALLERS ONLY iRect eRticaL eRmination For use with E20 Direct Vent Fireplace Insert. The Vertical Vent Cap is termination, rain cap, and a throat connector, it will ensure a tight seal, top performance, safety and efficiency. KIT COMPONENTS: Quantity Description Quantity...
  • Page 24 Initial Installation QUALIFIED INSTALLERS ONLY 6. Place a bead of high temperature silicone on the intake collar of the fireplace, slide the Ø2” (51mm) flex intake liner over the collar, secure the flex liner with three (3) sheet metal screws evenly spaced. 7.
  • Page 25: Solid Fuel Fireplace Installation

    Initial Installation QUALIFIED INSTALLERS ONLY oLiD iRepLace nstaLLation The base, sidewalls and top structure of the solid fuel firebox cannot be altered with the exception of: removal of dampers, removal of smoke shelf or baffle, removal of ember catches, removal of log grate, removal of viewing screen/curtain, and removal of doors.
  • Page 26: Electrical Requirements

    If any of the original wire as supplied with the appliance must be replaced, it must be replaced with 18 AWG wire with a temperature rating of 105°C Proflame 2 System (E20I) - Wiring Diagram Transmitter - TMFSLA (50-3265) / (0.584.040)
  • Page 27: Gas Line Connection & Testing

    Initial Installation QUALIFIED INSTALLERS ONLY & t onnection esting Warning: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. Gas Line Connection: • This stove is equipped with a certified flexible pipe located on the right side of the unit terminating in a 3/8”...
  • Page 28 Initial Installation QUALIFIED INSTALLERS ONLY TO TEST VALVE PRESSURES The pressure taps are located on the top right of the valve shown in Figure 41. • Turn set screw 1 turn counter clockwise to loosen, ” (8 mm) I.D. hose over pressure tap system. • Place • Check pressures using a manometer.
  • Page 29: Adjusting The Pilot Flame

    Initial Installation QUALIFIED INSTALLERS ONLY Djusting iLot Lame The pilot flow adjustment is pre-set to maximum at the factory and should not need to be adjusted. The pilot flame should envelope ⅜” to ½” (10 to 13mm) of the thermocouple (see Figure ). However, should the need arise, follow Steps 1- 3 below.
  • Page 30: Secondary Installation

    Secondary Installation & R ptionaL heLf iseR The E20 Base Shelf (1⅝” (41 mm) high) and Base Shelf Riser (2⅛” (54 mm) high) are components that can be combined to create a riser with an overall height of 2 ” (55 mm). This shelf can be installed with or without the riser and can be used when the hearth in front of the unit is lower than the fireplace opening.
  • Page 31: Optional 3 And 4 Sided Trim-Able Panels

    Secondary Installation ptionaL iDeD RimmabLe aneLs Modifying the Surround Panel: The E20 Trimable Surround Panels are large rectangular panels that may be cut for use in cases that a non-standard fireplace opening (e.g. an arched opening) is to be filled. Optionally this surround can be left uncut and placed in front of the fireplace opening.
  • Page 32: Surround Panel Installation

    Secondary Installation uRRounD aneL nstaLLation Warning: The surround becomes hot when the unit is operating; ensure that the unit is turned off, and that it has cooled to room temperature before begining this installation. Height Width 3-Sided Surrounds 24” (610 mm) ”...
  • Page 33: Safety Screen Installation

    Secondary Installation afety cReen nstaLLation The safety screen supplied with the unit must be Right Bracket Safety Screen Frame assembled first before it can be installed. When installed, the screen should not extrude out any farther than the surround panel if the cabinet extensions are still installed.
  • Page 34: Log And Glass Burner Options

    Secondary Installation og anD Lass uRneR ptions The E20 has two seperate burner styles ro choose from; a log burner and a glass burner. Installing the Log Burner: 1. Install the burner tray that comes with the kit into the E20 firebox by hanging the five holes on the back side over the 5 screws that come through the rear of the firebox.
  • Page 35: Optional Rocks For Glass Burner

    Secondary Installation ptionaL ocks foR Lass uRneR 1. Pour the glass beads into the tray being careful to leave a space in front of the pilot box (See Figure 61). 2. Add the first large rock in front of the pilot box as shown in Figure 62. It should rest on top of the burner and the pilot box.
  • Page 36: Firebox Liner Installation

    Secondary Installation iRebox ineR nstaLLation NOTE: The firebox liners are fragile and should be handled gently. The following instructions can be used for all firebox liner options. For simplicity, only the brick liner is shown. 1. Ensure the E20 is turned off and allow the unit to cool.
  • Page 37: Log Set And Ember Installation

    Secondary Installation et anD mbeR nstaLLation NOTE: The logs are fragile and should be handled gently. The placement of the logs is not arbitrary. If they are positioned incorrectly, the flames can be “pinched” and will not burn correctly. The burner and one of the logs come with locator pins and ledges, which make alignment easier.
  • Page 38 Secondary Installation Figure 70: The center of the right log fits against the back log. The front of the log is to rest on the burner and the back end of the log rests on the back brick panel. Ensure the log does not block any burn ports.
  • Page 39 Secondary Installation Figure 73. Log Set and Ember Installation. Figure 74. E20 complete log set-up with embers burning. NOTE: While the glass is still removed, it is recommended that the gas line be purged by lighting the pilot. When lighting the fireplace for the first time since the log set and embers have been installed/replaced, watch for ignition at ALL the burner ports.
  • Page 40: Trouble Shooting

    Trouble Shooting Problem Possible Cause Solution The main burner The gas valve may not be on. • Check that the gas control knob is in the “ON” position. does not ignite Thermostat is not calling for • Adjust the thermostat several degrees above ambient temperature. when called for.
  • Page 41: Parts List

    Parts List Reference Part Description Part Number Number E20 2” to 3” Air Intake Adaptor 50-1499 Flue Adapter Gasket 50-3376 E20 15’ 2” & 3” Flex Vent 50-1512 E20 2” & 3” Flex Couplers 50-1513 E20 Vertical Vent Cap 50-1487 E20 Flue Adaptor 50-3377 E20 Cabinet Back...
  • Page 42 Parts List PSE Pilot Assembly - Intermittant Pilot 50-3026 E20 Replacement Safety Screen 50-3071 12 oz. Can of Metallic Black Touch Up Paint PAINT-12-MB Reference Option Description Part Number Number Regular Surround Panel - E20 50-2250 Contemporary Surround Panel - E20 50-2252 Extruded Surround Panel - E20 50-2253...
  • Page 43: Parts Diagram - Components

    Parts Diagram - Components...
  • Page 44: Parts Diagram - Options

    Parts Diagram - Options...
  • Page 45: Notes

    Notes...
  • Page 46: Warranty

    Exclusions conditions herein set forth, this product against defects in material and workmanship An expanded list of exclusions is available at www.enviro.com/help/warranty.html during the specified warranty period starting from the date of original purchase at retail. This warranty does not cover: In the event of a defect of material or workmanship during the specified warranty period, ...
  • Page 47: Installation Data Sheet

    � NATURAL GAS (NAT) PROPANE(LPG) _________________________________________ INLET GAS PRESSURE:_________in WC PHONE:___________________________________ MAIN BURNER ORIFICE:__________# DMS PILOT ORIFICE #_________OR________in diam. INSTALLER’S SIGNATURE: _________________________________________ MANUFACTURED BY: SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD RD. SAANICHTON, BC, CANADA V8M 2A3 www.enviro.com March 23, 2017 C-15109...

Table of Contents