WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open flame.
• Do not try to light any appliance.
• Do not touch any electrical switch or use any phone
in your building.
• Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire
department.
This appliance may be installed in an after-market
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Installation and service must be performed by
a qualified installer, service agency or the gas
is used.
WARNING
supplier.
Massachusetts installations (Warning): This product must be installed by a licensed
plumber or gas fitter when installed within the Commonwealth of Massachusetts.
Other Massachusetts code requirements: Flexible connector must not be longer than
36in., a shut off valve must be installed; only direct vent sealed combustion products
are approved for bedrooms/bathrooms. A carbon monoxide detector is required in all
rooms containing gas fired direct vent appliances.
Retreat
D I R E C T V E N T F I R E P L A C E
B Y : S H E R W O O D I N D U S T R I E S L T D
Do not store or use gasoline or
other flammable vapours and
liquids in the vicinity of this or any
FOR YOUR SAFETY
other appliance.
50-1269

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ENVIRO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Enviro ENVIRO

  • Page 1 SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE OWNER’S MANUAL WHAT TO DO IF YOU SMELL GAS • Open windows/extinguish any open flame. • Do not try to light any appliance. •...
  • Page 2: Safety Precautions

    Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed in accordance with their instructions. Carefully read all the instructions in this manual first. Consult the building authority having jurisdiction to determine the need for a permit prior to commencing the installation.
  • Page 3: Table Of Contents

    Table of Contents Safety Precautions...2 Table of Contents...3 Codes And Approvals...4 Specifications...5 Dimensions...5 Rating Label Location...5 Operating Instructions...6 Pilot Lighting Instructions...6 Pilot Light...7 Air Shutter...7 Blower Speed...7 Burner Lighting...8 Remote Controls...8 Normal Sounds During Operation...8 Maintenance And Service...9 Routine Maintenance...9 Cleaning The Glass...9 Cleaning The Firebox...9 Replacing the Glass...9...
  • Page 4: Codes And Approvals

    After the unit has gone through the first burn, turn the unit off including the pilot, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner, available at your local ENVIRO dealer.
  • Page 5: Specifications

    INSTALLATION OPTIONS: • Parallel to a wall or placed in a corner • Vertical or horizontal venting WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. IMENSIONS "...
  • Page 6: Operating Instructions

    Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. ILOT IGHTING NSTRUCTIONS CAUTION: Hot while operating.
  • Page 7: Pilot Light

    Operating Instructions ILOT IGHT 1. Turn off the gas to the fireplace. If not recently done, remove the glass and let the unit air out for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints with soapy water.
  • Page 8: Burner Lighting

    After the unit has gone through the first burn, turn the unit OFF, including the pilot, and let the unit get completely cold. Then remove the glass and clean it with a good gas fireplace glass cleaner, available at your local Enviro dealer. See “M ” and “M...
  • Page 9: Maintenance And Service

    Do not operate your fireplace with the glass front removed, cracked or broken. Removal and replacement of the glass from the door must be done by a licensed or qualified service person. The glass must be purchased from an ENVIRO dealer. Substitute materials will void the warranty.
  • Page 10: Cleaning Decorative Surfaces

    Maintenance And Service LEANING ECORATIVE URFACES Painted and porcelain faces should be wiped with a damp cloth periodically. If a plated face has been purchased, it should be unpacked/unwrapped carefully to avoid getting anything on the surface of the finish, including cleaners, polish and finger prints. It is important to note that fingerprints and other marks can leave a permanent stain on plated finishes.
  • Page 11: Fuel Conversion

    Maintenance And Service ONVERSION TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before installing. Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction.
  • Page 12 Maintenance And Service Convert the SIT gas valve: a) Remove the black protection cap from the HI/LO knob by hand shown in Figure 9. Loosen Tighten Figure 10: Removing valve screw. g) Re-attach the black protection cap that was removed in step a (Figure 9).
  • Page 13: Initial Installation

    Initial Installation QUALIFIED INSTALLERS ONLY NTRODUCTION This section of the owner’s manual is for the use of qualified technicians only. Fireplace placement, hearths, facing, mantles, and venting terminations will be covered, as well as the gas and electric systems. There are several installation safety guidelines that must be adhered to. Please carefully read the safety precautions at the front of this manual.
  • Page 14: Placement And Framing

    Initial Installation LACEMENT AND RAMING A firestop is required through the rear wall. Ceiling " (1022mm) Min 6 " (165mm) 23" (584mm) Figure 17. Dimensions for Framing the Firebox. Table 3. Inlet Placement Dimensions, refer to Figure 1. Side Inlet: Distance back ”...
  • Page 15: Corner Installation

    Initial Installation QUALIFIED INSTALLERS ONLY The gas line, 3⁄8 inch NPT, can be brought to either the right side, the left side, or the bottom of the fireplace. If this set up is inconvenient, the electrical wire and the gas line configuration can be reversed.
  • Page 16: Framing Mount Brackets

    Initial Installation Figure 20. Raised Fireplace with Raised Hearth. Figure 21. Raised Fireplace with Floor Level Hearth. RAMING OUNT RACKETS Back Tabs; bent up & screwed into the wood framing Drywall Front Tabs; bent up & screwed into the drywall Figure 23.
  • Page 17: Wall Finishes

    Initial Installation QUALIFIED INSTALLERS ONLY INISHES Both of the Retreat faces will allow for up to a 1” (25 mm) thick finishing wall (example drywall and tile); see Figure 25 & 26. The wall may be finished up to the fireplace standoffs with combustible materials. This facing style should tuck under the bottom edge at the front bottom of the Retreat for concealment.
  • Page 18: Mantel Clearances

    Initial Installation ANTEL LEARANCES It is not necessary to install a mantel, but if one is desired it is important to follow the guidelines. Top of unit to 2x4 header framing: Top of unit to bottom of 3⁄4” (1.9 cm)-1” (2.5 cm) facing: 21⁄2” Top of unit to bottom of 31⁄2”...
  • Page 19: Vent Termination Restrictions

    Initial Installation QUALIFIED INSTALLERS ONLY ERMINATION ESTRICTIONS Fixed Closed Openable Termination Cap Figure 30. Vent Termination Restrictions, refer to Table 4. Table 4: Vent termination clearances, refer to Figure 30. Letter Canadian Installation 12 in (30 cm) 12 in (30 cm) 12 in (30 cm)* 24 in (60 cm)* 18 in (45 cm)*...
  • Page 20: Fireplace Horizontal Vent Kit 50-1235

    Initial Installation IREPLACE ORIZONTAL Please read and understand these instructions before installing. Failure to follow these instructions carefully could cause property damage or personal injury. KIT COMPONENTS: Qnty Description Horizontal direct vent termination cap Flue collar adapter Wall thimble 5’ (190 cm) length of Ø4” (10 cm) double walled flex pipe 5’...
  • Page 21: Other Approved Vent Parts

    Initial Installation QUALIFIED INSTALLERS ONLY 9. Install the flex pipe assembly through the wall thimble, ensure that this portion of pipe slides through the outside wall far enough to connect onto the vent termination cap. 10. Apply a bead of Mill-Pac Black sealant to the top section of the Ø4” (10 cm) by 5” (12.5 cm) flue collar adaptor previously installed into the fireplace flue outlet.
  • Page 22 Initial Installation WARNING: Do not mix parts from different vent manufacturers’s systems. EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems. Use of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the Intertek WH listing of the appliance.
  • Page 23: Venting

    Initial Installation QUALIFIED INSTALLERS ONLY ENTING This fireplace has been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE “GS” PIPE FOR GAS STOVES, SECURITY CHIMNEY’S SECURE VENT DIRECT VENT SYSTEM kits, AMERICAN METAL PRODUCTS AMERIVENT DIRECT and DIRECT-TEMP SELKIRK METALBESTOS. Wall Thimble 8"...
  • Page 24: Vent Configurations And Restrictor Settings

    Initial Installation ONFIGURATIONS AND Figures 31 shows the range of venting options, it shows possible vent configurations if the unit is top vented, for vertical and horizontal terminations, any layout that remains within the shaded area is acceptable. Having the fewest number of elbows is ideal, as they tend to disrupt air movement. Using 45˚...
  • Page 25: Horizontal Termination

    Initial Installation QUALIFIED INSTALLERS ONLY ORIZONTAL ERMINATION NOTES: 1. Horizontal pipes must not be level. For every 12 inches (305 mm) of horizontal travel (away from the stove), there should be at least 1⁄4 inch (6.4 mm) of vertical travel. Never allow the vent to run downward, as this could cause high temperatures or even present the possibility of a fire.
  • Page 26: Vertical Termination

    Initial Installation NOTE: For Simpson Duravent only, place a bead of Mil-Pac or Rutland No 78 Stove and Gasket Cement on the outer edge of the inner exhaust pipe (non-flared end). Push the pipe sections together, then twist about 1⁄4 turn, making sure the two sections are fully locked. Wrap all seams with foil ducting tape. Step 4.
  • Page 27 Initial Installation QUALIFIED INSTALLERS ONLY STEP 5. Cut hole in the roof centered on the small hole placed in the roof from Step 2. The hole should be of sufficient size to meet minimum requirements for Clearance to Combustibles, as specified. Continue to assemble lengths of pipe and elbows necessary to reach from the ceiling support box up through the roof line.
  • Page 28 Initial Installation plumber’s tape connected to wall strap Wall strap 45° elbows (x2) Figure 41. Use of Wall Straps. (4) Any occupied areas above the first floor, including closets and storage spaces, which the vertical vent passes through, must be enclosed. The enclosure may be framed and sheet-rocked with standard building materials.
  • Page 29: Electrical System For Thermostat

    Initial Installation QUALIFIED INSTALLERS ONLY LECTRICAL YSTEM HERMOSTAT CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. 20ft (6.1m) of bell wire is included with this unit. Determine the desired location of the thermostat or wall switch (if used).
  • Page 30: Gas Line Connection And Testing

    Initial Installation ONNECTION AND WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION This fireplace is equipped with a certified flexible pipe located on the right side of the unit. This •...
  • Page 31: Secondary Installation

    Secondary Installation QUALIFIED INSTALLERS ONLY PTIONAL NSTALLATION If the Retreat is installed, the burner and valve assemblies may need to be removed. If the Retreat is not installed the fan can be installed under the firebox, or through an access hole at the lower rear of the unit.
  • Page 32: Optional Fan Kit Installation Through Back Of Retreat

    Secondary Installation 5. Slide the fan temp sensor in place under the holding tabs above the SIT valve (see Figure 48). 6. Remove knob and nut from the fan controller. Place the knob stud through the fan hole in the control panel, the controller tab should align with the control panel hole (see Figure 49).
  • Page 33: Log Set And Ember Installation

    Secondary Installation 9. Remove knob and nut from the fan controller. Place the knob stud through the fan hole in the control panel, the controller tab should align with the control panel hole (see Figure 49). Tighten the nut on the front side to keep the fan controller in place (see Figure 50), then install the knob onto the stud.
  • Page 34: Installation Of Ceramic Firebox Liner

    A small amount on the bottom side of the logs is normal. Remove and replace the logs in the same manner described above. If new/more rock wool embers are required, contact your nearest ENVIRO dealer. Never operate the fireplace with the glass door removed. NSTALLATION OF ERAMIC IMPORTANT: A CERAMIC LINER MUST BE INSTALLED BEFORE UNIT IS LIT! Figure 58.
  • Page 35: Installation Of The Fascia

    Secondary Installation Figure 59. Slid In the Ceramic Liner. 3. Tilt the top of the liner slightly forward and slide one side of the liner into the firebox (see Figure 59 & 60). Ensure that the liner goes behind the pilot assembly as it is rotated into the firebox.
  • Page 36: Troubleshooting

    Problem Possible Cause The main burner does not The gas valve may not be on. ignite when called for. Thermostat is not calling for heat. Problem with gas valve. Spark will not light the pilot Defective piezo ignitor. after repeatedly pressing the spark ignitor.
  • Page 37: Parts List - Components

    S.I.T. Piezo Ignitor Burner Switch Fan Controller - 115V Convection Blower - 115V Convection Blower Kit- 115V Enviro Logo Gel Decal Blank Orifice #73 On/Off Remote Control Kit Programmable Wall Mounted Remote Control Dual Bulb Door Gasket - 10 feet (3.05m) Door, Glass, &...
  • Page 38: Parts List - Options

    Parts List - Options Reference Part Description Number Firebox Liner - Bankers Brown Brick Firebox Liner - Arizona Stucco Firebox Liner - Red Brick Fireplace Horizontal Vent Kit - 5 Feet (1.52 m) Fireplace Horizontal Vent Kit - 10 Feet (3.05 m) Chalet Face - Inset &...
  • Page 39: Parts Diagram - Components

    Parts Diagram - Components...
  • Page 40: Parts Diagram - Fascia

    Parts Diagram - Fascia The Retreat - Fascia July 2005...
  • Page 41: Installation Data Sheet

    Sherwood Industries Ltd. offers a Limited Lifetime Warranty on this gas product. This Limited Lifetime Warranty covers the appliance for a period of seven years from the date of installation. This warranty applies only to the original owner in the original location. Covered under the lifetime warranty are the chassis and the heat exchanger.
  • Page 42: Installation Data Sheet

    Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE:___________________________________ MODEL:___________________________________ SERIAL NUMBER:___________________________ DATE OF PURCHASE: _____________ DATE OF INSTALLATION:___________ � NATURAL GAS (NAT) INLET GAS PRESSURE:_________in WC MAIN BURNER ORIFICE:__________# DMS PILOT ORIFICE #_________OR________in diam.