N720 User Manual (Linux)
5 Establishing Connection Using RNDIS
N720 supports dialup and connection setup using RMNET with a VID of 0x2949 and a PID of 0x8241.
Send AT+NETSHAREMODE=2 to N720 to switch the configuration if t1.1he PID is not 0x8241.
5.1 Checking Device
Execute lsusb to check if N720 is identified.
N720 has been identified with a VID of 0x2949 and a PID of 0x8241.
5.2 Adding VID and PID
In kernel/drivers/usb/serial/option.c, add VID:0x2949 PID:0x8241 to option_ids.
5.3 Adding RNDIS Driver to Kernel
1.
Navigate to kernel and execute make menuconfig.
2.
Configure kernel. Select RNDIIS option and save the settings.
Device Drivers --->
-*- Network device support --->
{M}
USB Network Adapters --->
-M-
Multi-purpose USB Networking Framework (CONFIG_USB_NET=m)
-M-
Host for RNDIS and ActiveSync devices (CONFIG_USB_NET_RNDIS_HOST=m)
Copyright © Neoway Technology Co., Ltd