Motorola MTM800 Product Information Manual page 146

Tetra mobile terminals
Hide thumbs Also See for MTM800:
Table of Contents

Advertisement

3-32
Logging Mode:
Position the cursor into the combo box, then drag it to the required mode for the log file:
TEI & ITSI, SFPG and Normal
Normal
Off
If the Normal or TEI & ITSI, SFPG and Normal modes are selected, the CPS checks whether or
not the log file exists in the directory specified in the Log File Path field. If the file does not exist, the
CPS creates it with the name cps_user.log. If the log file exists, new information will be recorded into
it.
If the Off mode is selected, the logging of all operations will be disabled. If the log file already exists,
no operation will be recorded into it.
Normal. If the Normal mode is selected for communication operations through one port only, then
the recording of all log operations through the default port will be written into the cps_user.log file.
The logging of all operations will be enabled and performed according to the other logging page
settings.
TEI & ITSI, SFPG and Normal. If the ISSI & TEI Only mode is selected, then logging is similar to
the one in Normal mode and the CPS will also log any operation (through all ports related to the TEI,
ITSI and SFPG codeplug fields). The logging of all operations will be enabled and performed
according to the other logging page settings.
Log Options:
The following two options will be enabled if the user turns on the proper check boxes:
Write Time To Log
Write Operation Result To Log file
If these options are enabled, the time of the function start and the operation result (pass or fail) will
be appended to the new information recorded in the Log file.
Max log size:
This entry defines the maximum log file size. Click the slider to change the setting.The maximum
size is 200 MB.
Over write Log Info as Needed: The "enabled" setting means that all new events will be written to
the log, even when the log is full. When the log is full, each new event replaces the oldest one. The
"disabled" setting means that existing events will be retained when the log is full. If the maximum log
file size is reached, new events are discarded. This setting requires you to clear the log manually.
Select this setting only if you must retain all events.
Log File Path:
The CPS allows a directory to be set up for the Log file location through the Browse dialogue box,
which appears when clicking the Browse button. When the desired directory has been selected,
click the OK button and the path to the directory will be written to the Log file path field in the
Logging page. However, this path setting will be applied only in the next CPS session. Re-start the
CPS if the Log file path has been changed in the current session.
See Paragraph 7.7.4.4 "Directories".
6866537D87-F
Chapter 3 - MTM800 Product Information Manual
Customer Programming Software (CPS)
September 2008

Advertisement

Table of Contents
loading