SMA SUNNY HOME MANAGER Installation Manual page 38

Device for pv plant monitoring and load control
Hide thumbs Also See for SUNNY HOME MANAGER:
Table of Contents

Advertisement

7  Connection
9. If no energy meter is connected to the four-pole
plug, insert the four-pole plug into the
Sunny Home Manager in the lower pin row of one
of the connection sockets.
10. If an energy meter is connected to the four-pole
plug, insert the four-pole plug into the lower pin row
of the connection socket assigned to the given
energy meter (see Section 7.1 "Connection Area",
page 30).
11. Connect the AC connection cable to the top-hat rail
power supply unit (see the top-hat rail power supply unit manual).
12.
Danger to life due to electric shock
Lethal voltages are present at the connection point of the electricity grid.
• Disconnect the connection point from the electricity grid using the separator
(e.g. fuse box).
13. Connect the other end of the AC connection cable to the electricity supply.
14. Connect the connection point to the electricity grid.
☑ The status LED first glows red, then the status LED flashes red. After approximately
two minutes, the status LED switches to flashing green/orange intermittently.
✖ Is the status LED not intermittently flashing green and orange?
It is possible that the Sunny Home Manager is not correctly connected to the router.
• Ensure that the Sunny Home Manager is correctly connected to the router
(see Section 7.3).
38
HoMan-IA-en-13