Canon imageFORMULA DR-C125 Service Manual page 90

Hide thumbs Also See for imageFORMULA DR-C125:
Table of Contents

Advertisement

CHAPTER 5 TROUBLESHOOTING
set the value using the arrow keys
on the computer.
2) Place the scale parameter adjustment
sheet and display the screen. For details,
refer
to
the
Adjustment" section.
3) Execute manual registration adjustment if
required. For details, refer to the "Manual
Registration Adjustment" section.
4) Check the trailing edge of the image and
set the scale parameter adjustment
values. Note that these are the [Factory
Scale Parameter] values. For more
details, refer to the "Scale Parameter
Adjustment" section.
Note: Note that if the roller friction is
severe, the adjustment may not be
possible
with
Parameter] alone. In this case, you
should
also
Parameter], or replace the roller.
Figure 5-237
5-18
"Scale
Parameter
[Factory
Scale
use
[User
Scale
COPYRIGHT © CANON ELECTRONICS INC. 2011
With performing automatic registration
adjustment
This section gives the procedures for
performing
automatic
adjustment in this mode.
1) Click the [Reset] button. All of the values
change to zero. (Refer to Figure 5-238)
2) Execute
automatic
adjustment. For details, refer to the
"Automatic
Registration
section.
3) Next, perform the procedure from Step 2
in
the
previous
performing
automatic
adjustment ".
Figure 5-238
registration
registration
Adjustment"
section
"Without
registration
CANON DR-C125 FIRST EDITION