Canon imageFORMULA DR-C125 Service Manual page 88

Hide thumbs Also See for imageFORMULA DR-C125:
Table of Contents

Advertisement

CHAPTER 5 TROUBLESHOOTING
Note: The [User Scale Parameter] setting
value and the scale parameter
adjustment
value
Properties/Maintenance] on the user
operation screen are linked. Note
that the user value is displayed to
one decimal place with the value
rounded.
2.0mm
Figure 5-232
7) Place the adjustment sheet and scan
again. Check the displayed image.
Note: Repeat the procedure again if the
adjustments
properly.
5-16
in
[Utility/USB
were
not
corrected
COPYRIGHT © CANON ELECTRONICS INC. 2011
Figure 5-233
b. Automatic Registration Adjustment
The function of the [Registration
Adjustment] button is the same as section
"4. Registration Adjustment", and is linked
to the setting value. Place the registration
adjustment sheet and then click this button.
The set values are then displayed.
Figure 5-234
CANON DR-C125 FIRST EDITION

Advertisement

Table of Contents